# Yeager Airport — reinforced-slope failure and degraded rock

Case reference year: 2015 | Location: Charleston, West Virginia, United States

The reinforced slope supporting a runway extension failed in 2015. Published investigations examine the fill–rock interface, material strength selection and global failure mechanisms, offering a strong forensic capstone.

## Suggested capstone study

An original teaching brief based on the documented project. Study assumptions and student designs are separate from the built project.

Reconstruct a documented failure section and compare competing strength and groundwater assumptions against the observed failure geometry.

### Inputs to assemble

- Extract one internally consistent cross-section, foundation preparation detail and chronology from the selected author paper.
- Separate coarse reinforced-fill test results from softened or residual strengths at the fill–rock interface, recording drainage and sample scale.

### Deliverables

- Compare internal, compound and global mechanisms with sensitivity to interface strength and pore pressure.
- Prepare an improved investigation, construction-observation and movement-trigger plan, clearly distinguished from the actual historical design.
- A quantity takeoff and priced estimate with dated rate sources; separate historical project costs from the study estimate.
- A construction sequence, programme and risk register tied to investigation, access, monitoring and hold points.

### Review questions

- Why can strong geogrid and competent reinforced fill fail to prevent a mechanism controlled by the underlying weathered-rock interface?
- What would make a back-calculated strength plausible as a material property, rather than merely compensating for an incorrect geometry or groundwater model?

## Published project information

### Design — partial

The author studies discuss construction, performance and post-failure testing. The reinforced-slope height is reported differently across papers; retain the geometry and datum of the particular section being analysed instead of merging those values.

### Cost information — not-found

A project-specific estimate, bid schedule or final account was not found in the reviewed sources.

### Schedule information — partial

The failure occurred on 12 March 2015 after several years of service. The published papers separately describe construction and the observed pre-failure movements.

### Completion and records — partial

Post-failure investigation and analyses are documented; these sources are not a complete record of the later repair and acceptance programme.

## Published reference values

Use each value only within its stated scope. Reported costs have not been escalated or adjusted for inflation. These are source facts, not student design assumptions.

| Quantity | Value | Unit | Scope | Source locator |
| --- | ---: | --- | --- | --- |
| Slope height stated by Collin et al. | 67 | m | Reinforced-soil slope height in the Geotextiles and Geomembranes case-history title; retain that paper’s definition. | [Article title and case description](https://www.sciencedirect.com/science/article/pii/S0266114420300686) |
| Slope height stated by VandenBerge et al. | 73 | m | Height used in the ASCE case-history description; consult geometry and reference elevations before comparing with 67 m. | [Case-history description](https://ascelibrary.org/doi/10.1061/%28ASCE%29GT.1943-5606.0002430) |

## Project image

Yeager Airport photographed on 20 October 2026. This later site view is context for the 2015 reinforced-slope failure; it is not an image of the failure itself or a reconstruction drawing.

Credit: Designism / Wikimedia Commons
Image source: https://commons.wikimedia.org/wiki/File:KCRW_airport_aerial_20261020.jpg
Image rights: CC0 — https://creativecommons.org/publicdomain/zero/1.0/deed.en

## Sources

- Case history: failure of the reinforced soil slope at Yeager Airport (VandenBerge, Valentine, Brandon and Wright / ASCE; date not stated): https://ascelibrary.org/doi/10.1061/%28ASCE%29GT.1943-5606.0002430
- Case history on failure of a 67 m tall reinforced soil slope (Collin and coauthors / Geotextiles and Geomembranes; date not stated): https://www.sciencedirect.com/science/article/pii/S0266114420300686
- Stability and stress-deformation analyses — author-hosted paper (Investigation authors / The Collin Group; date not stated): https://www.thecollingroup.com/wp-content/uploads/2021/01/Collin-Yeager-Failure-JGGE-ASCE-GT.1943-5606.0002454.pdf
- KCRW airport aerial 20261020.jpg (Designism; 2026): https://commons.wikimedia.org/wiki/File:KCRW_airport_aerial_20261020.jpg

Sources checked: 2026-11-22. This brief is an original teaching aid. Source rights remain with their respective holders.