Cases / Project case study

Prudential Center — shallow foundations after improvement

The arena foundation study compared deep foundations with spread footings on improved ground. Test sections supported the selected compaction and replacement approach.

Shallow foundationsGround improvementSite investigationEstimating, sequencing and project delivery
The completed Prudential Center arena in Newark, New Jersey.
The completed Prudential Center arena in Newark, New Jersey. The photograph identifies the project discussed in the ground-improvement case history; the subsurface work is not visible.Bjoertvedt · Image source · CC BY-SA 4.0

Project evidence

Design & engineering

Partial record

The case describes trial treatment, foundation selection and protection of adjacent historic development.

Sources: s1

Cost & estimating

Partial record

The case reports roughly $1.5 million for improvement plus shallow foundations versus an estimated $3 million driven-pile alternative.

Sources: s1

Schedule & construction

Partial record

The case connects foundation selection to readiness for the 2007–2008 hockey season; a full contractor schedule is not supplied.

Sources: s1

Completion & performance

Partial record

Test-section and post-improvement field checks are discussed.

Sources: s1

Engineering methods

Foundation alternativesDynamic compactionTrial sections

Published quantities & cost references

These values retain the scope and date basis of their cited source. Estimates, alternatives and partial packages are identified individually.

Source-backed project quantities and costs
ItemReported valueScope & source
Improvement plus shallow foundations1,500,000 USDApproximate reported cost; not the arena total.As reported; no escalation or inflation adjustment.Source s1 · Cost Information
Driven-pile alternative3,000,000 USDOrder-of-magnitude estimated alternative; not an executed pile contract.As reported; no escalation or inflation adjustment.Source s1 · Cost Information
Trial-supported bearing pressure3 tsfReported allowable bearing pressure after trial assessment; not a transferable design value.Site-specific reported allowable value.Source s1 · Project Summary/Scope

Suggested teaching exercise

Capstone project brief

Perform a value-engineering comparison for a large building on heterogeneous urban fill while protecting neighbouring structures.

Starting information & inputs

  • Extract the trial-section results and stated allowable-bearing assumptions.
  • Separate measured treatment response from the original designers’ interpreted bearing values.

Suggested deliverables

  • Check bearing, differential settlement and vibration-sensitive construction zones.
  • Prepare an alternatives matrix with cost scope and construction-risk allowances.
  • A quantity takeoff and priced estimate with dated rate sources; separate historical project costs from the study estimate.
  • A construction sequence, programme and risk register tied to investigation, access, monitoring and hold points.

Design questions

  • Which site data control the decision, and what additional investigation would reduce uncertainty?
  • How would the proposed solution change under the stated sensitivity cases, construction constraints and performance limits?

The brief is a proposed educational exercise based on the cited project, not the original designer's instruction or a complete construction document set.

Sources & original records

Prudential Center, Newark, New Jersey ↗

ASCE Geo-Institute / named case-history author · 2013

Case author Chris Woods; technical paper Woods, Drumheller and Huber (2013).

public-link · Publisher-hosted; redistribution permission not established · Checked 2026-11-22