Explore the data
Loading the data preview…
Columns, features & units
View the full data dictionary · 34 columns
| Column | Meaning | Unit | Data coverage |
|---|---|---|---|
| c01 | Destination (-)Source field retained without unit conversion. | - | text0 missing |
| c02 | Horizontal distance (m)Source field retained without unit conversion. | m | number0 to 1581 missing |
| c03 | sampling_name (-)Source field retained without unit conversion. | - | text0 missing |
| c04 | CPT_nameSource field retained without unit conversion. | — | text1,006 to 1,0060 missing |
| c05 | Depth (m)Source field retained without unit conversion. | m | number0.08 to 53.210 missing |
| c06 | qc (MPa)Source field retained without unit conversion. | MPa | number0.08 to 80.0230 missing |
| c07 | fs (MPa)Source field retained without unit conversion. | MPa | number-0.0012 to 0.941010 missing |
| c08 | Rf (%)Source field retained without unit conversion. | % | number-0.20152 to 16.1290 missing |
| c09 | u2 (MPa)Source field retained without unit conversion. | MPa | number-0.4549 to 2.40120 missing |
| c10 | gamma (kN/m3)Source field retained without unit conversion. | kN/m3 | number1.85 to 22.515362 missing |
| c11 | gamma_d (kN/m3)Source field retained without unit conversion. | kN/m3 | number0.8 to 21.191,007 missing |
| c12 | OCR (-)Source field retained without unit conversion. | - | number0.98079 to 26.31,334 missing |
| c13 | e0 (-)Source field retained without unit conversion. | - | number0.27206 to 24.71,326 missing |
| c14 | phi_CD (degree)Source field retained without unit conversion. | degree | number24 to 47.81,331 missing |
| c15 | cohesion_CD (kPa)Source field retained without unit conversion. | kPa | number0 to 81.61,331 missing |
| c16 | phi_RS_peak (degree)Source field retained without unit conversion. | degree | number17.643 to 32.9741,542 missing |
| c17 | phi_RS_residual (degree)Source field retained without unit conversion. | degree | number16.842 to 31.9591,542 missing |
| c18 | phi_SB (degree)Source field retained without unit conversion. | degree | number29 to 361,512 missing |
| c19 | cohesion_SB (kPa)Source field retained without unit conversion. | kPa | number0 to 321,512 missing |
| c20 | su_CU_undisturbed (kPa)Source field retained without unit conversion. | kPa | number6.9 to 8751,248 missing |
| c21 | su_CUe_undisturbed (kPa)Source field retained without unit conversion. | kPa | number7.1 to 257.751,507 missing |
| c22 | su_DSS (kPa)Source field retained without unit conversion. | kPa | number5.9 to 275.71,379 missing |
| c23 | su_UU_remoulded (kPa)Source field retained without unit conversion. | kPa | number15.5 to 323.41,525 missing |
| c24 | su_UU_undisturbed (kPa)Source field retained without unit conversion. | kPa | number35 to 306.21,520 missing |
| c25 | water_content (%)Source field retained without unit conversion. | % | number3.5427 to 1,0961,137 missing |
| c26 | torvane (kPa)Source field retained without unit conversion. | kPa | number13 to 2001,532 missing |
| c27 | pocket_penetrometer (kPa)Source field retained without unit conversion. | kPa | number42.5 to 333.331,526 missing |
| c28 | E50ref (MPa)Source field retained without unit conversion. | MPa | number4.4276 to 54.2011,519 missing |
| c29 | E50ref_m_parameter (-)Source field retained without unit conversion. | - | number0.5 to 11,519 missing |
| c30 | E50_sigma3_eff (kPa)Source field retained without unit conversion. | kPa | text1,502 missing |
| c31 | E50 (MPa)Source field retained without unit conversion. | MPa | text1,502 missing |
| c32 | Eoed (MPa)Source field retained without unit conversion. | MPa | number0.1 to 26.71,216 missing |
| c33 | su_FCT (kPa)Source field retained without unit conversion. | kPa | number7.1 to 711,512 missing |
| c34 | SBTSource field retained without unit conversion. | Not stated | number0 to 90 missing |
Test context & data notes
- Included file
- Dataset2_Coupled_Geotechnical_CPT.parquet
- Source dimensions
- 1544 rows × 34 columns
- Only Dataset2 is included locally. The publisher’s 311 MB Dataset1 sounding archive remains linked at the source.
- Repeated sampling/sounding keys are retained. Nearby CPT values and laboratory results may be spatially coupled rather than identical specimens; keep the horizontal-distance column and grouping identifiers.
- String-valued E50 and effective-stress fields retain source strings. Unknown units remain unspecified.
Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.
Files, size & reuse
| File | Format / size | Download |
|---|---|---|
coupled-cpt-laboratory-full.csvColumn keys normalized where necessary. Published numerical values, missing tokens and row order retained. No imputation or recalculation.File checksumSHA256 ac10ad56d88a11538cbd3fb675ee3473cac9892070e6158c43508e3154e71e1f | CSV215.4 KB · 215,360 bytes | Download |
Dataset2_Coupled_Geotechnical_CPT.parquetOriginal bytes unchanged; publisher checksum verified.File checksumSHA256 f3c2ca975fbaccf86813ccdfb8eb646d5c5e91f58ba575d86f2af9872e53e95a | PARQUET101.7 KB · 101,693 bytes | Download |
Reuse: CC BY 4.0 · Read the terms
These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.
Source & citation
Felic, Haris; Yaz, Ali; Tschuchnigg, Franz (2026). A Dataset for Data-Driven Soil Characterization: Cone Penetration Test Soundings and CPT-Coupled Laboratory Parameters (V1). Zenodo. https://doi.org/10.5281/zenodo.21793782 DOI: 10.5281/zenodo.21793782.
Source version: V1 · retrieved 2026-11-22