Laboratory tests · Laboratory dataset

Kaolin permeability — GeoTac1

Garcia & Waite / USGS

Permeability/conductivity values from the publisher’s inter-device comparison.

8 data rows6 columnsUnited States

Explore the data

Loading the data preview…

Columns, features & units

Void ratioVertical effective stressMid-step void ratioMid-step stressPermeabilityHydraulic conductivity (published)
View the full data dictionary · 6 columns
ColumnMeaningUnitData coverage
void_ratioVoid ratioSource field retained without unit conversion.-number0.58108 to 1.63090 missing
stress_mpaVertical effective stressSource field retained without unit conversion.MPanumber0.01389 to 5.99760 missing
mid_void_ratioMid-step void ratioSource field retained without unit conversion.-number0.63267 to 1.60020 missing
mid_stress_mpaMid-step stressSource field retained without unit conversion.MPanumber0.020855 to 4.70541 missing
permeability_mdPermeabilitySource field retained without unit conversion.mDnumber0.013075 to 0.335961 missing
conductivity_msHydraulic conductivity (published)Source field retained without unit conversion.m/snumber0.00000000012646 to 0.00000000324931 missing

Test context & data notes

Source worksheet
Permeability
Measurement approach
Consolidation log-time interpretation
  • Publisher-computed permeability and conductivity values are retained. No conversion or formula execution is performed.
  • A source prose note states water density 1 kg/m³, which appears inconsistent with common water density and its displayed conductivity values. Use the original workbook and cited methodology; this website does not silently correct it.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
kaolin-permeability-geotac1.csvColumn keys normalized where necessary. Published numerical values, missing tokens and row order retained. No imputation or recalculation.
File checksumSHA256 7722ff1c9c55cbdeb9d24aed7fea5faa2d7a31200f5c7493e01d219fbba559fd
CSV944 B · 944 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Garcia, Adrian V.; Waite, William (2025). Compressibility and permeability data for kaolin: a comparison between 1-dimensional oedometers and a high-stress permeameter. Zenodo. https://doi.org/10.5281/zenodo.15021308 DOI: 10.5281/zenodo.15021308.

View the primary source