Physical model tests · Physical model test

Model pile — Rectangular — Table6 (condition ambiguity)

Huda Wogod / University of Baghdad

Published load and settlement measurements from Table6.

24 data rows2 columnsIraq

Explore the data

Loading the data preview…

Columns, features & units

LoadSettlement
View the full data dictionary · 2 columns
ColumnMeaningUnitData coverage
load_nLoadSource field retained without unit conversion.Nnumber0 to 11.980 missing
settlement_mmSettlementSource field retained without unit conversion.mmnumber-26.985 to 00 missing

Test context & data notes

Source table
6
Geometry and condition
Rectangular — Table6 (condition ambiguity)
  • Repeated zero rows and negative settlement readings are preserved; inspect the source sign convention before comparison.
  • TheTable6 caption says dry, while the surrounding sequence/figure references suggest the saturated rectangular test. The condition is left ambiguous rather than silently relabelled.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
pile-load-table-6.csvColumn keys normalized where necessary. Published numerical values, missing tokens and row order retained. No imputation or recalculation.
File checksumSHA256 8d9d87b04f284aebeeb512bd2898b3bd891818e0c7d690e19183720b5b63291a
CSV438 B · 438 bytes Download

Reuse: CC BY 4.0 · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

Wogod, Huda (2025). Experimental load-settlement data for square, circular, and rectangular piles.. Zenodo. https://doi.org/10.5281/zenodo.18156334 DOI: 10.5281/zenodo.18156334.

View the primary source

Source version: Zenodo record 18156334 · retrieved 2026-11-22