Field investigations · CPT sounding

CPT HNC005 — Henderson, Kentucky

U.S. Geological Survey

Published cone penetration profile with 400 depth readings to 20 m. Original site metadata and measurement signs are retained.

400 data rows5 columnsKentucky, United States

Explore the data

Loading the data preview…

Columns, features & units

Depth (m)Tip resistance (MPa)Sleeve friction (kPa)Cone inclination (°)S-wave travel time (ms)
View the full data dictionary · 5 columns
ColumnMeaningUnitData coverage
depth_mDepthmnumber0.05 to 200 missing
tip_resistance_mpaTip resistanceMPanumber0.62 to 32.830 missing
sleeve_friction_kpaSleeve frictionkPanumber-32,768 to 347.50 missing
inclination_degCone inclination°number0.04 to 8.070 missing
s_wave_time_msS-wave travel timemsnumber13.42 to 98.51390 missing

Test context & data notes

Sounding
HNC005
State
Kentucky
County
Henderson
State (original header)
KENTUCKY
County (original header)
HENDERSON
Test date (publisher table)
2003-12-06
Test date (original header)
12/06/03
Deepest measurement (m)
20
Total depth (original header, m)
20.00
Water depth (original header, m)
>0
Longitude (publisher table)
-87.70189667
Latitude (publisher table)
37.87210083
UTM datum (original header)
NAD1927
UTM grid zone
16S
Original source
USGS
  • Original USGS TXT bytes are retained. The companion CSV renames headers and removes metadata/empty optional columns; measurement values and numeric signs are unchanged.
  • USGS legacy-table coordinates and original header metadata are both retained. The table does not document the coordinate datum; consult the original UTM datum before combining spatial datasets.
  • Depth samples within one sounding are correlated. Split machine-learning evaluation by sounding/site, not randomly by adjacent rows.
  • 5 negative resistance/friction values are present as published. No missing-value or sensor-failure interpretation has been inferred, and these values remain in the CSV and preview.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
HNC005.csvHeaders normalized; published numeric values retained; metadata stays in original TXT and catalog.
File checksumSHA256 fd84c6f5e92088a0b479bf817af8dd09ee21fa7a24f694b955af2431386ffda4
CSV8.7 KB · 8,688 bytes Download
HNC005.txt
File checksumSHA256 1e316e396f99effdae5de237581ff281a0007a376f904d02db62f3e152f006af
TXT8.8 KB · 8,829 bytes Download

Reuse: U.S. public domain · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

U.S. Geological Survey. Legacy Cone Penetration Testing data, sounding HNC005. https://earthquake.usgs.gov/research/cpt/data/txt/HNC005.txt (retrieved 2026-11-22).

View the primary source

Source version: Legacy online TXT, retrieved 2026-11-22 · retrieved 2026-11-22