Field investigations · CPT sounding

CPT MYC100 — Monterey, California

U.S. Geological Survey

Published cone penetration profile with 193 depth readings to 19.3 m. Original site metadata and measurement signs are retained.

193 data rows4 columnsCalifornia, United States

Explore the data

Loading the data preview…

Columns, features & units

Depth (m)Tip resistance (MPa)Sleeve friction (kPa)Cone inclination (°)
View the full data dictionary · 4 columns
ColumnMeaningUnitData coverage
depth_mDepthmnumber0.1 to 19.30 missing
tip_resistance_mpaTip resistanceMPanumber0.34 to 18.550 missing
sleeve_friction_kpaSleeve frictionkPanumber-3,200 to 222.40 missing
inclination_degCone inclination°number0 to 00 missing

Test context & data notes

Sounding
MYC100
State
California
County
Monterey
State (original header)
CA
County (original header)
Monterey
Test date (publisher table)
1993-08-31
Test date (original header)
8/31/1993
Deepest measurement (m)
19.3
Total depth (original header, m)
19.3
Water depth (original header, m)
1.8
Longitude (publisher table)
-121.79263
Latitude (publisher table)
36.87828
UTM datum (original header)
1927 NAD
UTM grid zone
10S
Original source
USGS
  • Original USGS TXT bytes are retained. The companion CSV renames headers and removes metadata/empty optional columns; measurement values and numeric signs are unchanged.
  • USGS legacy-table coordinates and original header metadata are both retained. The table does not document the coordinate datum; consult the original UTM datum before combining spatial datasets.
  • Depth samples within one sounding are correlated. Split machine-learning evaluation by sounding/site, not randomly by adjacent rows.
  • 1 negative resistance/friction values are present as published. No missing-value or sensor-failure interpretation has been inferred, and these values remain in the CSV and preview.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
MYC100.csvHeaders normalized; published numeric values retained; metadata stays in original TXT and catalog.
File checksumSHA256 dbe2ac941cdc630906cf6bb28a48f4cb1426a94ab03793bafdea1fbf9f5d0083
CSV3.4 KB · 3,396 bytes Download
MYC100.txt
File checksumSHA256 82040f1acf102be4bb8ffe11c89c1e9a75328b6902e6f89f074b10b4fa75b8a2
TXT4.0 KB · 4,033 bytes Download

Reuse: U.S. public domain · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

U.S. Geological Survey. Legacy Cone Penetration Testing data, sounding MYC100. https://earthquake.usgs.gov/research/cpt/data/txt/MYC100.txt (retrieved 2026-11-22).

View the primary source

Source version: Legacy online TXT, retrieved 2026-11-22 · retrieved 2026-11-22