Field investigations · CPT sounding

CPT OBN002 — Obion, Tennessee

U.S. Geological Survey

Published cone penetration profile with 410 depth readings to 20.5 m. Original site metadata and measurement signs are retained.

410 data rows5 columnsTennessee, United States

Explore the data

Loading the data preview…

Columns, features & units

Depth (m)Tip resistance (MPa)Sleeve friction (kPa)Cone inclination (°)S-wave travel time (ms)
View the full data dictionary · 5 columns
ColumnMeaningUnitData coverage
depth_mDepthmnumber0.05 to 20.50 missing
tip_resistance_mpaTip resistanceMPanumber0.73 to 30.220 missing
sleeve_friction_kpaSleeve frictionkPanumber-32,768 to 553.860 missing
inclination_degCone inclination°number1.42 to 5.640 missing
s_wave_time_msS-wave travel timemsnumber13.44 to 101.01399 missing

Test context & data notes

Sounding
OBN002
State
Tennessee
County
Obion
State (original header)
Tennessee
County (original header)
Obion
Test date (publisher table)
2008-10-14
Test date (original header)
10/14/08
Deepest measurement (m)
20.5
Total depth (original header, m)
20.5
Longitude (publisher table)
-89.45028687
Latitude (publisher table)
36.28268051
UTM datum (original header)
NAD27
UTM grid zone
16S
Original source
USGS
  • Original USGS TXT bytes are retained. The companion CSV renames headers and removes metadata/empty optional columns; measurement values and numeric signs are unchanged.
  • USGS legacy-table coordinates and original header metadata are both retained. The table does not document the coordinate datum; consult the original UTM datum before combining spatial datasets.
  • Depth samples within one sounding are correlated. Split machine-learning evaluation by sounding/site, not randomly by adjacent rows.
  • 2 negative resistance/friction values are present as published. No missing-value or sensor-failure interpretation has been inferred, and these values remain in the CSV and preview.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
OBN002.csvHeaders normalized; published numeric values retained; metadata stays in original TXT and catalog.
File checksumSHA256 2c2a0f3e04a29ff353cafc43ed6a39ec0f57633722a05832663efa8c5d7624ad
CSV10.3 KB · 10,270 bytes Download
OBN002.txt
File checksumSHA256 2b28c0afbf9665d02eb7c205ee78b47752c0bc491f2a736000691266715f7651
TXT10.9 KB · 10,864 bytes Download

Reuse: U.S. public domain · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

U.S. Geological Survey. Legacy Cone Penetration Testing data, sounding OBN002. https://earthquake.usgs.gov/research/cpt/data/txt/OBN002.txt (retrieved 2026-11-22).

View the primary source

Source version: Legacy online TXT, retrieved 2026-11-22 · retrieved 2026-11-22