Field investigations · CPT sounding

CPT SFC002 — Saint Francis, Arkansas

U.S. Geological Survey

Published cone penetration profile with 442 depth readings to 22.1 m. Original site metadata and measurement signs are retained.

442 data rows5 columnsArkansas, United States

Explore the data

Loading the data preview…

Columns, features & units

Depth (m)Tip resistance (MPa)Sleeve friction (kPa)Cone inclination (°)S-wave travel time (ms)
View the full data dictionary · 5 columns
ColumnMeaningUnitData coverage
depth_mDepthmnumber0.05 to 22.10 missing
tip_resistance_mpaTip resistanceMPanumber0.48 to 30.360 missing
sleeve_friction_kpaSleeve frictionkPanumber-32,768 to 3880 missing
inclination_degCone inclination°number0.03 to 7.930 missing
s_wave_time_msS-wave travel timemsnumber13.57 to 107.03431 missing

Test context & data notes

Sounding
SFC002
State
Arkansas
County
Saint Francis
State (original header)
ARKANSAS
County (original header)
SAINT FRANCIS
Test date (publisher table)
2003-10-03
Test date (original header)
10/03/03
Deepest measurement (m)
22.1
Total depth (original header, m)
22.10
Water depth (original header, m)
>.8
Longitude (publisher table)
-90.43759918
Latitude (publisher table)
35.04901886
UTM datum (original header)
NAD27
UTM grid zone
15S
Original source
USGS
  • Original USGS TXT bytes are retained. The companion CSV renames headers and removes metadata/empty optional columns; measurement values and numeric signs are unchanged.
  • USGS legacy-table coordinates and original header metadata are both retained. The table does not document the coordinate datum; consult the original UTM datum before combining spatial datasets.
  • Depth samples within one sounding are correlated. Split machine-learning evaluation by sounding/site, not randomly by adjacent rows.
  • 2 negative resistance/friction values are present as published. No missing-value or sensor-failure interpretation has been inferred, and these values remain in the CSV and preview.

Check the source documentation and test conditions before combining records. Preserve collection, site and specimen identifiers when preparing machine-learning splits.

Files, size & reuse

FileFormat / sizeDownload
SFC002.csvHeaders normalized; published numeric values retained; metadata stays in original TXT and catalog.
File checksumSHA256 28876421ee4460e572c671e153a845a16658fc7b8a61ca941da63777f46abd88
CSV9.7 KB · 9,700 bytes Download
SFC002.txt
File checksumSHA256 700944650e6d9a7a7ebfdcc57dd3b2cf24c7e217203215964cd6e8c1c03550a9
TXT10.3 KB · 10,276 bytes Download

Reuse: U.S. public domain · Read the terms

These files are available directly from Foundation Design. Original files retain their publisher content; any normalized table is identified with its conversion notes.

Source & citation

U.S. Geological Survey. Legacy Cone Penetration Testing data, sounding SFC002. https://earthquake.usgs.gov/research/cpt/data/txt/SFC002.txt (retrieved 2026-11-22).

View the primary source

Source version: Legacy online TXT, retrieved 2026-11-22 · retrieved 2026-11-22