Strip footing — simplified bearing capacity

Shallow Foundation, Bearing Capacity

By Foundation Design Example Library

400 Rank #18 Views 9,654
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Strip footing -- simplified bearing capacity} \subsection{Application and idealization} Strip footing, vertical centered loading, level ground, drained soil. \subsection{Governing equations} $q_u=c^{\prime}N_c+\gamma D N_q+\tfrac12\gamma BN_{\gamma}$, using a specified Vesic-type $N_{\gamma}$ approximation. \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ B & Footing or section width (m) & m & 2 \\ D & Embedment depth (m) & m & 1 \\ phi & Effective friction angle (degrees) & deg & 30 \\ c & Effective cohesion (kPa) & kPa & 10 \\ gamma & Soil unit weight (kN/m3) & kN/m3 & 18 \\ FS & Specified factor of safety (-) & - & 3 \\ \end{longtable} \subsection{Calculation procedure} \[ r = \frac{\phi\,\pi}{180} \] \[ \mathrm{Nq} = \operatorname{exp}\left(\pi\,\operatorname{tan}\left(r\right)\right)\,\operatorname{tan}\left(\frac{\pi}{4}+\frac{r}{2}\right)^{2} \] \[ \mathrm{Nc} = \frac{\mathrm{Nq}-1}{\operatorname{tan}\left(r\right)} \] \[ \mathrm{Ng} = 2\,\left(\mathrm{Nq}+1\right)\,\operatorname{tan}\left(r\right) \] \[ \mathrm{qu} = c\,\mathrm{Nc}+\gamma\,D\,\mathrm{Nq}+0.5\,\gamma\,B\,\mathrm{Ng} \] \begin{itemize} \item Ultimate gross bearing pressure: \( \mathrm{qu} \). \item Allowable gross pressure (simplified): \( \frac{\mathrm{qu}}{\mathrm{FS}} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Ultimate gross bearing pressure: 1035.8612 kPa. \item Allowable gross pressure (simplified): 345.28708 kPa. \end{itemize} \subsection{Assumptions and interpretation} Excludes bearing inclination, water table corrections, local/punching shear and settlement. \subsection{Accepted input ranges} \begin{itemize} \item Footing or section width (m): 0.05 to 100 m. \item Embedment depth (m): 0 to 100 m. \item Effective friction angle (degrees): 1 to 48 deg. \item Effective cohesion (kPa): 0 to 1000 kPa. \item Soil unit weight (kN/m3): 1 to 35 kN/m3. \item Specified factor of safety (-): 1.01 to 20 -. \end{itemize} \subsection{Reference and scope} FHWA Geotechnical Engineering Circular No. 6, Shallow Foundations (2002). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/010943.pdf} Shallow-foundation and serviceability background; the app is a bounded implementation of its stated idealization. \end{document}

Engineering Calculator

Engineering Calculation Results