Eccentric footing — rectangular soil contact

Shallow Foundation, Bearing Capacity

By Foundation Design Example Library

372 Rank #22 Views 4,866
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Eccentric footing -- rectangular soil contact} \subsection{Application and idealization} Rigid rectangular base under axial load plus moment, no soil tension. \subsection{Governing equations} $e=M/P$, full contact for $e\le B/6$, triangular compression for $B/6<e<B/2$. \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ P & Applied vertical load (kN) & kN & 900 \\ M & Overturning moment about width axis (kNm) & kNm & 80 \\ B & Footing or section width (m) & m & 2 \\ L & Length (m) & m & 3 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{ecc} = \frac{M}{P} \] \[ a = 3\,\left(\frac{B}{2}-\mathrm{ecc}\right) \] \[ \mathrm{qmax} = \begin{cases}\frac{P}{B\,L}\,\left(1+\frac{6\,\mathrm{ecc}}{B}\right)&\mathrm{ecc}\leq \frac{B}{6}\\\begin{cases}\frac{2\,P}{a\,L}&\mathrm{ecc}<\frac{B}{2}\\0&\text{otherwise}\end{cases}&\text{otherwise}\end{cases} \] \[ \mathrm{qmin} = \begin{cases}\frac{P}{B\,L}\,\left(1-\frac{6\,\mathrm{ecc}}{B}\right)&\mathrm{ecc}\leq \frac{B}{6}\\0&\text{otherwise}\end{cases} \] \begin{itemize} \item Resultant eccentricity: \( \mathrm{ecc} \). \item Maximum contact pressure: \( \mathrm{qmax} \). \item Minimum contact pressure: \( \mathrm{qmin} \). \item Contact width for compression-only case: \( \begin{cases}B&\mathrm{ecc}\leq \frac{B}{6}\\\begin{cases}a&\mathrm{ecc}<\frac{B}{2}\\0&\text{otherwise}\end{cases}&\text{otherwise}\end{cases} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Resultant eccentricity: 0.088888889 m. \item Maximum contact pressure: 190 kPa. \item Minimum contact pressure: 110 kPa. \item Contact width for compression-only case: 2 m. \end{itemize} \subsection{Assumptions and interpretation} When e >= B/2 stability is not satisfied and qmax=0 is a failure flag; check output eccentricity. \subsection{Accepted input ranges} \begin{itemize} \item Applied vertical load (kN): 0 to 1000000000 kN. \item Overturning moment about width axis (kNm): 0 to 100000000 kNm. \item Footing or section width (m): 0.05 to 100 m. \item Length (m): 0.05 to 1000 m. \end{itemize} \subsection{Reference and scope} FHWA Geotechnical Engineering Circular No. 6, Shallow Foundations (2002). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/010943.pdf} Shallow-foundation and serviceability background; the app is a bounded implementation of its stated idealization. \end{document}

Engineering Calculator

Engineering Calculation Results