Hydrostatic uplift under footing slab

Shallow Foundation, Bearing Capacity

By Foundation Design Example Library

305 Rank #57 Views 3,982
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Hydrostatic uplift under footing slab} \subsection{Application and idealization} Uniform hydrostatic pressure acting over horizontal area. \subsection{Governing equations} $U=\gamma_w h_w A$. \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ B & Footing or section width (m) & m & 2 \\ L & Length (m) & m & 3 \\ hw & Water head at base (m) & m & 2 \\ gamma\_w & Unit weight of water (kN/m3) & kN/m3 & 9.81 \\ dead & Total resisting dead weight (kN) & kN & 1700 \\ \end{longtable} \subsection{Calculation procedure} Substitute the input values into the governing output equation. \begin{itemize} \item Hydrostatic uplift force: \( \mathrm{gamma\_w}\,\mathrm{hw}\,B\,L \). \item Resisting-to-uplift ratio: \( \frac{\mathrm{dead}}{\mathrm{gamma\_w}\,\mathrm{hw}\,B\,L+0.000001} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Hydrostatic uplift force: 117.72 kN. \item Resisting-to-uplift ratio: 14.441046. \end{itemize} \subsection{Assumptions and interpretation} Ignores transient seepage and partial contact; near-zero head FS is regularized, not a meaningful design value. \subsection{Accepted input ranges} \begin{itemize} \item Footing or section width (m): 0.05 to 100 m. \item Length (m): 0.05 to 1000 m. \item Water head at base (m): 0 to 100 m. \item Unit weight of water (kN/m3): 9 to 11 kN/m3. \item Total resisting dead weight (kN): 0.01 to 1000000000 kN. \end{itemize} \subsection{Reference and scope} FHWA Geotechnical Engineering Circular No. 6, Shallow Foundations (2002). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/010943.pdf} Shallow-foundation and serviceability background; the app is a bounded implementation of its stated idealization. \end{document}

Engineering Calculator

Engineering Calculation Results