Pile tension resistance — side friction + dead weight

Deep Foundation, Drive Piles-Bearing Capacity

By Foundation Design Example Library

299 Rank #60 Views 6,300
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Pile tension resistance -- side friction + dead weight} \subsection{Application and idealization} Simple side resistance and effective pile weight for axial uplift. \subsection{Governing equations} $Q_{u,up}=Q_{s,up}+W_{pile}^{\prime}$. \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ Qs & Ultimate uplift shaft resistance (kN) & kN & 420 \\ Wp & Effective pile dead weight (kN) & kN & 55 \\ FS & Specified factor of safety (-) & - & 3 \\ \end{longtable} \subsection{Calculation procedure} Substitute the input values into the governing output equation. \begin{itemize} \item Ultimate uplift resistance: \( \mathrm{Qs}+\mathrm{Wp} \). \item Allowable uplift resistance: \( \frac{\mathrm{Qs}+\mathrm{Wp}}{\mathrm{FS}} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Ultimate uplift resistance: 475 kN. \item Allowable uplift resistance: 158.33333 kN. \end{itemize} \subsection{Assumptions and interpretation} No anchorage, cyclic effects, buoyancy beyond supplied effective weight, or load-test calibration. \subsection{Accepted input ranges} \begin{itemize} \item Ultimate uplift shaft resistance (kN): 0 to 1000000000 kN. \item Effective pile dead weight (kN): 0 to 100000000 kN. \item Specified factor of safety (-): 1.01 to 20 -. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results