Excavation plug — confined-aquifer uplift

Groundwater & Seepage, Uplift and Excavations

By Foundation Design Method Library

127 Rank #138 Views 1,973
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Excavation plug - confined-aquifer uplift} \subsection{Purpose} Check the vertical force balance of the remaining soil plug above a pressurized confined aquifer during excavation. The aquifer pressure head is referenced to the aquifer roof, making the pressure datum explicit. \subsection{Method and governing equations} \[ U/A=\gamma_wh_b,\qquad W/A=\gamma_{\mathrm{sat}}D+\gamma_wh_t+q \] \[ FS_{\mathrm{uplift}}=\frac{\gamma_{\mathrm{sat}}D+\gamma_wh_t+q}{\gamma_wh_b} \] \subsection{Inputs, symbols and units} \begin{itemize} \item \textbf{Remaining soil-plug thickness above aquifer roof} ($\mathtt{D}$): m. Default 5. \item \textbf{Saturated total unit weight of plug} ($\mathtt{gsat}$): kN/m3. Default 20. \item \textbf{Aquifer pressure head measured above its roof} ($\mathtt{hb}$): m. Default 10. \item \textbf{Water depth above the excavation base} ($\mathtt{ht}$): m. Default 0. \item \textbf{Other downward surcharge on remaining plug} ($\mathtt{q}$): kPa. Default 0. \item \textbf{Water unit weight} ($\mathtt{gw}$): kN/m3. Default 10. \end{itemize} \subsection{Interpreting the results} Track the aquifer head during excavation and account for the actual thickness remaining at every stage. Relief pumping or a changed construction stage must be assessed through a consistent groundwater and force-balance model. \subsection{Worked default example} \begin{itemize} \item Downward-to-upward pressure ratio: 1 -. \item Aquifer uplift pressure at plug base: 100 kPa. \item Total downward pressure: 100 kPa. \item Net downward pressure margin: 0 kPa. \item Aquifer pressure head at neutral force balance: 10 m. \end{itemize} \subsection{Verification example} The benchmark has 5 m of soil weighing 20 kN/m3 and 10 m of aquifer pressure head at water unit weight 10 kN/m3. Both downward and upward pressures are exactly 100 kPa. The verification case uses the default inputs listed above. Expected benchmark quantities: \begin{itemize} \item Downward-to-upward pressure ratio: 1. \item Aquifer uplift pressure at plug base: 100. \item Total downward pressure: 100. \item Net downward pressure margin: 0. \item Aquifer pressure head at neutral force balance: 10. \end{itemize} \subsection{Assumptions and limits} The plug is treated as a coherent, laterally extensive block with no beneficial side shear, anchors or tensile strength. Use the groundwater pressure applicable to the excavation stage, including possible delayed equalization or artesian pressure. This total-force check does not solve seepage, internal erosion, local defects, uplift bending or undrained basal heave. A neutral ratio of 1 has no design margin. \subsection{References} USACE EM 1110-2-1901, Seepage Analysis and Control for Dams. Piezometric head, uplift pressure and seepage control concepts. \url{https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-1901.pdf} Pressure integration and force balance are derived independently from measured head; no seepage field is solved. \end{document}

Engineering Calculator

Engineering Calculation Results