CPTu dissipation — Teh–Houlsby t50 interpretation

Laboratory & Site Characterization, Cone Penetration

By Foundation Design Method Library

205 Rank #101 Views 4,957
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{CPTu dissipation - Teh-Houlsby t50 interpretation} \subsection{Purpose} Interpret a measured t50 from a monotonic piezocone dissipation curve using the Teh-Houlsby modified time factor for the actual pore-pressure element location. The initial and equilibrium pressures define the target reading. \subsection{Method and governing equations} \[ c_h=\frac{T^*_{50}a^2\sqrt{I_r}}{t_{50}},\qquad u_{50}=\frac{u_i+u_0}{2} \] \[ T^*_{50}=0.118\ (u_1),\qquad T^*_{50}=0.245\ (u_2) \] \subsection{Inputs, symbols and units} \begin{itemize} \item \textbf{Pore-pressure element position} ($\mathtt{type}$): -. Default 1. 0 = u1 at cone mid-face; 1 = u2 behind cone tip. \item \textbf{Cone radius} ($\mathtt{a}$): mm. Default 17.85. \item \textbf{Rigidity index G/su} ($\mathtt{Ir}$): -. Default 100. \item \textbf{Time to 50 percent excess-pressure dissipation} ($\mathtt{t50}$): s. Default 200. \item \textbf{Initial pore pressure after stopping penetration} ($\mathtt{ui}$): kPa. Default 300. \item \textbf{Equilibrium pore-water pressure} ($\mathtt{u0}$): kPa. Default 100. \end{itemize} \subsection{Interpreting the results} Confirm the measured curve reaches the stated 50 percent excess-pressure level and record the assumed rigidity index. Compare the inferred ch with the scale and drainage direction of the intended application. \subsection{Worked default example} \begin{itemize} \item Horizontal consolidation coefficient: 0.000003903125625 m2/s. \item Horizontal consolidation coefficient per day: 0.337230054 m2/day. \item Pore pressure defining the 50 percent reading: 200 kPa. \item Selected modified time factor: 0.245 -. \end{itemize} \subsection{Verification example} The stored benchmark is an independently evaluated identity or worked numerical case, not a value copied from the runtime output. The verification case changes the following default inputs; all other inputs retain the defaults listed above. \begin{itemize} \item $\mathtt{type}=1$: -. \item $\mathtt{a}=20$: mm. \item $\mathtt{Ir}=100$: -. \item $\mathtt{t50}=100$: s. \item $\mathtt{ui}=300$: kPa. \item $\mathtt{u0}=100$: kPa. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Horizontal consolidation coefficient: 0.0000098. \item Horizontal consolidation coefficient per day: 0.84672. \item Pore pressure defining the 50 percent reading: 200. \item Selected modified time factor: 0.245. \end{itemize} \subsection{Assumptions and limits} Use a saturated, normally to lightly overconsolidated fine-grained soil with a monotonic positive excess-pressure response. t50 is measured from stopping cone advance; it is not calculated from two arbitrary readings. Delayed pressure maxima, dilative stiff clays, element saturation problems and uncertain rigidity can require a different interpretation. Horizontal ch is not interchangeable with laboratory vertical cv. \subsection{References} FHWA GEC 5, Geotechnical Site Characterization (2016). FHWA GEC 5, section 6.13.1, equation 6.19 and Table 6-7 (Teh and Houlsby 1991).. \url{https://highways.dot.gov/sites/fhwa.dot.gov/files/FHWA-NHI-16-072.pdf} Data reduction and explicitly calibrated correlations; these tools do not replace soil sampling, local validation or a complete site investigation. \end{document}

Engineering Calculator

Engineering Calculation Results