Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Image well - recharge or barrier boundary} \subsection{Purpose} Represent one straight aquifer boundary by reflecting the pumping well across it. An image injection well maintains the specified head at a recharge boundary; an image extraction well cancels normal flow at a barrier. \subsection{Method and governing equations} \[ r_r^2=(x-a)^2+y^2,\qquad r_i^2=(x+a)^2+y^2 \] \[ s_j\simeq\frac{Q}{4\pi T}[-\gamma_E-\ln u_j],\quad u_j=\frac{r_j^2S}{4Tt} \] \[ s=s_r-s_i\ \text{(constant head)},\qquad s=s_r+s_i\ \text{(no flow)} \] \subsection{Inputs, symbols and units} \begin{itemize} \item \textbf{Straight boundary condition} ($\mathtt{boundary}$): -. Default 0. 0 = Constant-head recharge boundary; 1 = Impermeable no-flow boundary. \item \textbf{Constant pumping rate} ($\mathtt{Q}$): m3/day. Default 1000. \item \textbf{Aquifer transmissivity} ($\mathtt{T}$): m2/day. Default 100. \item \textbf{Aquifer storativity} ($\mathtt{S}$): -. Default 0.001. \item \textbf{Well distance from boundary x = 0} ($\mathtt{a}$): m. Default 50. \item \textbf{Observation x on pumping side of boundary} ($\mathtt{x}$): m. Default 20. \item \textbf{Observation offset parallel to boundary} ($\mathtt{y}$): m. Default 20. \item \textbf{Time since pumping started} ($\mathtt{t}$): day. Default 10. \end{itemize} \subsection{Interpreting the results} Inspect the sign of the image contribution and compare the total with the real-well result. Exactly on a constant-head boundary, the two contributions cancel. A barrier increases drawdown. \subsection{Worked default example} \begin{itemize} \item Real-well drawdown contribution: 5.932078513 m. \item Image-well contribution: -4.81374244 m. \item Total boundary-adjusted drawdown: 1.118336073 m. \item Image-well Theis parameter: 0.001325 -. \end{itemize} \subsection{Verification example} At x = 0, the distances to the real and reflected wells are identical: a recharge boundary therefore has exactly zero drawdown. Tests also verify that the no-flow case doubles the real-well response there. The verification case changes the following default inputs; all other inputs retain the defaults listed above. \begin{itemize} \item $\mathtt{x}=0$: m. \item $\mathtt{y}=0$: m. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Total boundary-adjusted drawdown: 0. \end{itemize} \subsection{Assumptions and limits} Use the half-plane x >= 0 with the real well at (a,0). The confined-aquifer assumptions of the Theis solution apply. Both well distances must meet u <= 0.01, enforced using the more distant image well. The logarithmic solution is a late-time approximation, not a general early-time or finite-river-conductance model. \subsection{References} The Groundwater Project, Using Superposition to Represent Simple Boundary Conditions. Section 11.2, image-well construction for recharge and impermeable boundaries. \url{https://books.gw-project.org/an-introduction-to-hydraulic-testing-in-hydrogeology/chapter/using-superposition-to-represent-simple-boundary-conditions/} A single straight boundary represented by a reflected injection or extraction well. The Groundwater Project, An Introduction to Hydraulic Testing in Hydrogeology. Section 8.1, formulation and series for the Theis equation. \url{https://books.gw-project.org/an-introduction-to-hydraulic-testing-in-hydrogeology/chapter/formulation-of-the-theis-equation/} Constant-rate, fully penetrating line-source pumping in an infinite homogeneous confined aquifer. \end{document}

Engineering Calculator

Engineering Calculation Results