Foundation uplift — three piezometer pressure diagram

Groundwater & Seepage, Uplift and Excavations

By Foundation Design Method Library

135 Rank #132 Views 2,162
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Foundation uplift - three piezometer pressure diagram} \subsection{Purpose} Integrate a measured piecewise-linear uplift-pressure diagram under a base. Two trapezoids give the uplift force and its position, allowing the measured water pressures to enter a separate stability assessment. \subsection{Method and governing equations} \[ U_i=\frac{(p_i+p_{i+1})L_i}{2},\qquad p_i=\gamma_w h_i \] \[ M_i=x_iU_i+\frac{L_i^2(p_i+2p_{i+1})}{6},\qquad \bar x=\frac{\sum M_i}{\sum U_i} \] \[ FS_{\mathrm{force}}=\frac{W}{U},\qquad N=W-U \] \subsection{Inputs, symbols and units} \begin{itemize} \item \textbf{Base length in the flow direction} ($\mathtt{B}$): m. Default 10. \item \textbf{Middle piezometer distance from left edge} ($\mathtt{x1}$): m. Default 5. \item \textbf{Left pressure head above base} ($\mathtt{h0}$): m. Default 2. \item \textbf{Middle pressure head above base} ($\mathtt{h1}$): m. Default 1. \item \textbf{Right pressure head above base} ($\mathtt{h2}$): m. Default 0.5. \item \textbf{Water unit weight} ($\mathtt{gw}$): kN/m3. Default 9.81. \item \textbf{Downward resultant per metre of base width} ($\mathtt{W}$): kN/m. Default 500. \end{itemize} \subsection{Interpreting the results} Use the resultant location with the actual base weight and other force resultants in a moment check. A positive net force alone does not establish adequate bearing or sliding resistance. \subsection{Worked default example} \begin{itemize} \item Integrated uplift force: 110.3625 kN/m. \item Resultant location from left edge: 3.888888889 m. \item Downward-to-uplift force ratio: 4.530524408 -. \item Net downward force: 389.6375 kN/m. \end{itemize} \subsection{Verification example} The benchmark is an exactly triangular pressure diagram rising from 0 to 100 kPa over 10 m: area 500 kN/m and centroid two-thirds of the base length from the zero-pressure end. The verification case changes the following default inputs; all other inputs retain the defaults listed above. \begin{itemize} \item $\mathtt{B}=10$: m. \item $\mathtt{x1}=5$: m. \item $\mathtt{h0}=0$: m. \item $\mathtt{h1}=5$: m. \item $\mathtt{h2}=10$: m. \item $\mathtt{gw}=10$: kN/m3. \item $\mathtt{W}=1000$: kN/m. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Integrated uplift force: 500. \item Resultant location from left edge: 6.666666667. \item Downward-to-uplift force ratio: 2. \item Net downward force: 500. \end{itemize} \subsection{Assumptions and limits} Heads are pressure heads above the base elevation at each point, not total heads to a common datum unless that datum is the base. The base is horizontal and the result is per metre out of plane. Linear interpolation between only three piezometers can miss local pressure peaks. Downward force must include the intended weight and external loads; no overturning, shear, anchorage or bearing check is performed. \subsection{References} USACE EM 1110-2-1901, Seepage Analysis and Control for Dams. Piezometric head, uplift pressure and seepage control concepts. \url{https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-1901.pdf} Pressure integration and force balance are derived independently from measured head; no seepage field is solved. \end{document}

Engineering Calculator

Engineering Calculation Results