Mononobe–Okabe — smooth vertical wall

Earth Retaining Structures, Seismic Earth Pressure

By Foundation Design Method Library

130 Rank #136 Views 2,867
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Mononobe-Okabe - smooth vertical wall} \subsection{Purpose} Evaluate total pseudo-static active thrust for a smooth vertical wall retaining dry, level, cohesionless backfill. The input sign of kv is defined through the effective gravity factor 1-kv, so the inertia convention is explicit. \subsection{Method and governing equations} \[ \theta=\tan^{-1}\left(\frac{k_h}{1-k_v}\right),\qquad \theta<\phi' \] \[ K_{AE}=\frac{\cos^2(\phi'-\theta)}{\cos^2\theta\left[1+\sqrt{\frac{\sin\phi'\sin(\phi'-\theta)}{\cos\theta}}\right]^2} \] \[ P_{AE}=\frac12\gamma H^2(1-k_v)K_{AE},\qquad P_A=\frac12\gamma H^2\frac{1-\sin\phi'}{1+\sin\phi'} \] \subsection{Inputs, symbols and units} \begin{itemize} \item \textbf{Retained height} ($\mathtt{H}$): m. Default 6. \item \textbf{Dry backfill unit weight} ($\mathtt{gamma}$): kN/m3. Default 20. \item \textbf{Effective backfill friction angle} ($\mathtt{phi}$): deg. Default 30. \item \textbf{Horizontal seismic coefficient} ($\mathtt{kh}$): -. Default 0.15. \item \textbf{Vertical coefficient; positive reduces effective gravity} ($\mathtt{kv}$): -. Default 0. \end{itemize} \subsection{Interpreting the results} Use the total thrust in a consistent seismic stability model with the project-selected coefficients. Avoid adding a separate static thrust to Pae, because Pae already includes the static component. \subsection{Worked default example} \begin{itemize} \item Seismic active coefficient Kae: 0.4329383431 -. \item Static active coefficient Ka: 0.3333333333 -. \item Total seismic active thrust: 155.8578035 kN/m. \item Static active thrust: 120 kN/m. \item Change from static thrust: 35.85780352 kN/m. \item Inertial angle theta: 8.53076561 deg. \end{itemize} \subsection{Verification example} The zero-acceleration benchmark reduces exactly to Rankine Ka = 1/3 at phi = 30 degrees. A separate test maximizes the force equilibrium of trial planar wedges at nonzero kh and compares it with the closed-form coefficient. The verification case changes the following default inputs; all other inputs retain the defaults listed above. \begin{itemize} \item $\mathtt{kh}=0$: -. \item $\mathtt{kv}=0$: -. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Seismic active coefficient Kae: 0.3333333333. \item Static active coefficient Ka: 0.3333333333. \item Total seismic active thrust: 120. \item Static active thrust: 120. \item Change from static thrust: 0. \end{itemize} \subsection{Assumptions and limits} The wall must move enough to mobilize an active wedge. Wall friction, wall batter, backfill slope, surcharge, groundwater and cohesion are all zero in this specialization. The inertial angle must stay below the friction angle. This is not a displacement analysis or a dynamic pressure distribution; the app does not assign an application height to the seismic increment. Seismic passive resistance is not computed. \subsection{References} FHWA GEC 3, LRFD Seismic Analysis and Design of Transportation Geotechnical Features and Structural Foundations (2011). Section 11.3.1, Mononobe-Okabe seismic active earth-pressure theory. \url{https://highways.dot.gov/sites/fhwa.dot.gov/files/FHWA-NHI-11-032.pdf} Dry active wedge, sufficient wall movement and valid inertial geometry. No seismic passive-pressure expression is used. \end{document}

Engineering Calculator

Engineering Calculation Results