Ground anchor: bonded length and pullout capacity

Earth Retaining Structures, Anchored Walls

By Foundation Design Example Library

334 Rank #42 Views 6,063
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Ground anchor: bonded length and pullout capacity} \subsection{Application and idealization} Simplified grouted anchor bond length and pullout resistance screening. \subsection{Governing equations} $K_0=1-\sin\phi$, $Q_u=\pi d L K_0\sigma_v^{\prime}\tan\delta$, $FS=Q_u/T_{service}$. \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ D & Average anchor depth & m & 8 \\ L & Bonded length & m & 8 \\ phi & Soil friction angle & deg & 32 \\ delta & Grout-soil interface friction & deg & 22 \\ gamma & Effective unit weight & kN/m\(^{3}\) & 10 \\ q & Surface surcharge & kPa & 10 \\ anchor\_diameter & Grout bulb diameter & m & 0.15 \\ P\_design & Design tensile load & kN & 200 \\ SF\_required & Required pullout FS & - & 2 \\ \end{longtable} \subsection{Calculation procedure} Use the selected input values in the numerical method described above. The output list below states the reported quantities. Simplified grouted anchor bond length and pullout resistance screening. \subsection{Worked example using default inputs} \begin{itemize} \item Anchor interface resistance: 64.440016 kN. \item Allowable pullout: 32.220008 kN. \item Applied anchor load: 200 kN. \item Pullout FS: 0.32220008. \item Required FS: 2. \item Effective overburden: 90 kPa. \item Assumed at-rest coefficient K0: 0.47008074. \end{itemize} \subsection{Assumptions and interpretation} Preliminary grouted-anchor bond capacity using an assumed K0 radial stress and interface friction. Grout-soil bond strength, installation quality, group effects, and long-term creep require specific testing. \subsection{Accepted input ranges} \begin{itemize} \item Average anchor depth: 0.1 to 100 m. \item Bonded length: 0.1 to 100 m. \item Soil friction angle: 5 to 49 deg. \item Grout-soil interface friction: 2 to 45 deg. \item Effective unit weight: 3 to 24 kN/m\(^{3}\). \item Surface surcharge: 0 to 1000 kPa. \item Grout bulb diameter: 0.03 to 3 m. \item Design tensile load: 0.01 to 10000000 kN. \item Required pullout FS: 1 to 10 -. \end{itemize} \subsection{Reference and scope} FHWA GEC No. 4, Ground Anchors and Anchored Systems (1999). \url{https://www.fhwa.dot.gov/engineering/geotech/library_sub.cfm?keyword=020} Anchor system and test interpretation background; acceptance criteria must come from the project specification. \end{document}

Engineering Calculator

Engineering Calculation Results