Groundwater exit gradient, boiling safety and seepage

Soil Improvement, Ground Improvement

By Foundation Design Example Library

371 Rank #24 Views 8,955
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Groundwater exit gradient, boiling safety and seepage} \subsection{Application and idealization} Upward seepage, boiling/heave factor of safety and groundwater discharge. \subsection{Governing equations} $i=\Delta h/L$, $i_c=(\gamma_{sat}-\gamma_w)/\gamma_w$, $FS=i_c/i$, $Q=kiA$. \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ headDifference & Upward head difference & m & 2 \\ L & Seepage flow length & m & 5 \\ gamma\_sat & Saturated soil unit weight & kN/m\(^{3}\) & 20 \\ gamma\_w & Water unit weight & kN/m\(^{3}\) & 9.81 \\ SF\_target & Required boiling FS & - & 1.5 \\ k & Hydraulic conductivity & m/s & 0.00001 \\ area & Flow area & m\(^{2}\) & 25 \\ \end{longtable} \subsection{Calculation procedure} Use the selected input values in the numerical method described above. The output list below states the reported quantities. Upward seepage, boiling/heave factor of safety and groundwater discharge. \subsection{Worked example using default inputs} \begin{itemize} \item Hydraulic gradient: 0.4. \item Critical boiling gradient: 1.038736. \item Boiling FS: 2.59684. \item Target FS: 1.5. \item Darcy discharge: 0.0001 m\(^{3}\)/s. \item Excess hydraulic head margin: 1.4624533 m. \end{itemize} \subsection{Assumptions and interpretation} Quick check for upward-flow heave/boiling and Darcy seepage; layered anisotropic deposits, piping and concentrated seepage paths are not represented. \subsection{Accepted input ranges} \begin{itemize} \item Upward head difference: 0.01 to 500 m. \item Seepage flow length: 0.1 to 500 m. \item Saturated soil unit weight: 10 to 35 kN/m\(^{3}\). \item Water unit weight: 8 to 11 kN/m\(^{3}\). \item Required boiling FS: 1 to 5 -. \item Hydraulic conductivity: 1e-12 to 0.1 m/s. \item Flow area: 0.01 to 100000 m\(^{2}\). \end{itemize} \subsection{Reference and scope} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://rosap.ntl.bts.gov/view/dot/41551} Background for soil properties, stress, strength, seepage and settlement; this tool implements only the equations stated here. \end{document}

Engineering Calculator

Engineering Calculation Results