Falling-head laboratory permeability test reduction

Soil Improvement, Ground Improvement

By Foundation Design Method Library

7 Rank #246 Views 237
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Falling-head laboratory permeability test reduction} \subsection{Application and idealization} Reduce a conventional one-dimensional falling-head permeability test using measured standpipe area, specimen dimensions, head ratio and elapsed time. \subsection{Governing equations} \[ k=\frac{aL}{At}\ln\left(\frac{h_1}{h_2}\right) \] \[ k_{m/s}=k_{cm/s}/100 \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ a & Standpipe internal cross-sectional area & cm\(^{2}\) & 0.8 \\ A & Soil specimen cross-sectional area & cm\(^{2}\) & 40 \\ L & Soil specimen length & cm & 10 \\ h1 & Initial hydraulic head & cm & 90 \\ h2 & Final hydraulic head & cm & 35 \\ t & Elapsed test time & s & 260 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{ratio} = \frac{\mathrm{h1}}{\mathrm{h2}} \] \[ \mathrm{k\_cm\_s} = \frac{a\,L}{A\,t}\,\ln\left(\mathrm{ratio}\right) \] \[ \mathrm{k\_m\_s} = \frac{\mathrm{k\_cm\_s}}{100} \] \begin{itemize} \item Measured head ratio h1/h2: \( \mathrm{ratio} \). \item Hydraulic conductivity: \( \mathrm{k\_cm\_s} \). \item Hydraulic conductivity SI: \( \mathrm{k\_m\_s} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Measured head ratio h1/h2: 2.5714286. \item Hydraulic conductivity: 0.00072650893 cm/s. \item Hydraulic conductivity SI: 0.0000072650893 m/s. \item Head trend: Decreasing head -- valid direction. \end{itemize} \subsection{Assumptions and interpretation} Laminar saturated Darcy flow, stable water temperature, negligible specimen deformation, no sidewall leakage; final head must be smaller than initial head for physical validity. \subsection{Accepted input ranges} \begin{itemize} \item Standpipe internal cross-sectional area: 0.001 to 500 cm\(^{2}\). \item Soil specimen cross-sectional area: 0.01 to 5000 cm\(^{2}\). \item Soil specimen length: 0.1 to 100 cm. \item Initial hydraulic head: 0.1 to 1000 cm. \item Final hydraulic head: 0.01 to 1000 cm. \item Elapsed test time: 0.1 to 10000000 s. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://rosap.ntl.bts.gov/view/dot/41551} Background for soil properties, stress, strength, seepage and settlement; this tool implements only the equations stated here. \end{document}

Engineering Calculator

Engineering Calculation Results