Flow-net seepage discharge and exit-gradient safety

Earth Retaining Structures, Earth Pressure Prediction

By Foundation Design Method Library

31 Rank #230 Views 378
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Flow-net seepage discharge and exit-gradient safety} \subsection{Application and idealization} Use a conventional curvilinear flow net to estimate seepage discharge and the head loss per potential drop at an assumed exit element. \subsection{Governing equations} \[ q= k H (N_f/N_d) \] \[ i_{exit}\approx H/(N_d\ell_{exit}) \] \[ i_c=(G_s-1)/(1+e_0) \] \[ FS=i_c/i_{exit} \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ k & Saturated hydraulic conductivity & m/s & 0.00001 \\ H & Total hydraulic head drop & m & 6 \\ Nf & Number of flow channels & - & 4 \\ Nd & Number of potential drops & - & 12 \\ le & Approximate length of exit drop & m & 0.75 \\ Gs & Specific gravity of solids & - & 2.65 \\ e0 & Void ratio & - & 0.7 \\ FS\_req & Target factor of safety & - & 1.5 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{qprime} = \frac{k\,H\,\mathrm{Nf}}{\mathrm{Nd}} \] \[ \mathrm{exit\_i} = \frac{H}{\mathrm{Nd}\,\mathrm{le}} \] \[ \mathrm{ic} = \frac{\mathrm{Gs}-1}{1+\mathrm{e0}} \] \[ \mathrm{FS} = \frac{\mathrm{ic}}{\mathrm{exit\_i}} \] \begin{itemize} \item Seepage discharge per unit out-of-plane width: \( \mathrm{qprime} \). \item Average exit hydraulic gradient: \( \mathrm{exit\_i} \). \item Approximate critical boiling gradient: \( \mathrm{ic} \). \item Exit-gradient factor of safety: \( \mathrm{FS} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Seepage discharge per unit out-of-plane width: 0.00002 m\(^{2}\)/s. \item Average exit hydraulic gradient: 0.66666667. \item Approximate critical boiling gradient: 0.97058824. \item Exit-gradient factor of safety: 1.4558824. \item Design check: Does not meet target. \end{itemize} \subsection{Assumptions and interpretation} Steady two-dimensional saturated isotropic seepage, approximately curvilinear square elements; exit-element geometry must be verified. \subsection{Accepted input ranges} \begin{itemize} \item Saturated hydraulic conductivity: 1e-11 to 1 m/s. \item Total hydraulic head drop: 0.001 to 100 m. \item Number of flow channels: 1 to 50 -. \item Number of potential drops: 1 to 100 -. \item Approximate length of exit drop: 0.01 to 100 m. \item Specific gravity of solids: 1.1 to 4 -. \item Void ratio: 0.01 to 4 -. \item Target factor of safety: 1 to 8 -. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results