Equivalent permeability of two horizontal soil layers

Soil Improvement, Ground Improvement

By Foundation Design Method Library

34 Rank #226 Views 635
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Equivalent permeability of two horizontal soil layers} \subsection{Application and idealization} Horizontal flow sees layer conductivities in parallel; vertical flow sees them in series. Compute equivalent hydraulic conductivities and discharge. \subsection{Governing equations} \[ k_h=\frac{k_1h_1+k_2h_2}{h_1+h_2} \] \[ k_v=\frac{h_1+h_2}{h_1/k_1+h_2/k_2} \] \[ Q=k_v i A \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ k1 & Layer 1 hydraulic conductivity & m/s & 0.00002 \\ k2 & Layer 2 hydraulic conductivity & m/s & 5e-7 \\ h1 & Layer 1 thickness & m & 2.5 \\ h2 & Layer 2 thickness & m & 3.5 \\ i & Applied hydraulic gradient & - & 0.3 \\ A & Area normal to flow & m\(^{2}\) & 10 \\ \end{longtable} \subsection{Calculation procedure} \[ H = \mathrm{h1}+\mathrm{h2} \] \[ \mathrm{kh} = \frac{\mathrm{k1}\,\mathrm{h1}+\mathrm{k2}\,\mathrm{h2}}{H} \] \[ \mathrm{kv} = \frac{H}{\frac{\mathrm{h1}}{\mathrm{k1}}+\frac{\mathrm{h2}}{\mathrm{k2}}} \] \[ \mathrm{Qv} = \mathrm{kv}\,i\,A \] \begin{itemize} \item Horizontal equivalent conductivity: \( \mathrm{kh} \). \item Vertical equivalent conductivity: \( \mathrm{kv} \). \item Layer-induced permeability anisotropy: \( \frac{\mathrm{kh}}{\mathrm{kv}} \). \item Vertical Darcy discharge: \( \mathrm{Qv} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Horizontal equivalent conductivity: 0.000008625 m/s. \item Vertical equivalent conductivity: 8.4210526e-7 m/s. \item Layer-induced permeability anisotropy: 10.242188. \item Vertical Darcy discharge: 0.0000025263158 m\(^{3}\)/s. \end{itemize} \subsection{Assumptions and interpretation} Two saturated homogeneous horizontal layers, steady laminar flow obeying Darcy law; excludes anisotropy within each layer and boundary bypass. \subsection{Accepted input ranges} \begin{itemize} \item Layer 1 hydraulic conductivity: 1e-11 to 1 m/s. \item Layer 2 hydraulic conductivity: 1e-11 to 1 m/s. \item Layer 1 thickness: 0.01 to 500 m. \item Layer 2 thickness: 0.01 to 500 m. \item Applied hydraulic gradient: 0 to 20 -. \item Area normal to flow: 0.001 to 1000000 m\(^{2}\). \end{itemize} \subsection{Reference and scope} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://rosap.ntl.bts.gov/view/dot/41551} Background for soil properties, stress, strength, seepage and settlement; this tool implements only the equations stated here. \end{document}

Engineering Calculator

Engineering Calculation Results