Seismic cyclic stress demand and liquefaction FS screening

Slope Stability, Seismic Screening

By Foundation Design Method Library

10 Rank #245 Views 181
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Seismic cyclic stress demand and liquefaction FS screening} \subsection{Application and idealization} Calculate simplified equivalent earthquake cyclic stress demand and compare with a separately determined cyclic resistance ratio. Resistance CRR7.5 and the site/magnitude correction factors must come from an independent qualified procedure. \subsection{Governing equations} \[ CSR=0.65(a_{max}/g)(sigma_{v0}/sigma_{v0}^{prime})r_d \] \[ CRR=CRR_{7.5},MSF,K_{sigma} \] \[ FS_{liq}=CRR/CSR \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ amax & Peak horizontal acceleration ratio amax/g & - & 0.25 \\ sv & Total overburden stress & kPa & 150 \\ sve & Effective overburden stress & kPa & 85 \\ rd & Depth stress-reduction factor & - & 0.92 \\ CRR75 & Reference cyclic resistance ratio for Mw 7.5 & - & 0.18 \\ MSF & Magnitude scaling factor & - & 1 \\ Ksigma & Confining stress correction & - & 1 \\ FS\_req & Required triggering safety factor & - & 1.1 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{CSR} = 0.65\,\mathrm{amax}\,\frac{\mathrm{sv}}{\mathrm{sve}}\,\mathrm{rd} \] \[ \mathrm{CRR} = \mathrm{CRR75}\,\mathrm{MSF}\,\mathrm{Ksigma} \] \[ \mathrm{FS} = \frac{\mathrm{CRR}}{\mathrm{CSR}} \] \begin{itemize} \item Equivalent cyclic stress ratio demand: \( \mathrm{CSR} \). \item Corrected cyclic resistance ratio: \( \mathrm{CRR} \). \item Preliminary triggering safety factor: \( \mathrm{FS} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Equivalent cyclic stress ratio demand: 0.26382353. \item Corrected cyclic resistance ratio: 0.18. \item Preliminary triggering safety factor: 0.68227425. \item Screening check: Further liquefaction assessment indicated. \end{itemize} \subsection{Assumptions and interpretation} Saturated potentially liquefiable ground; this is a simplified stress-based triggering ratio, not a liquefaction hazard determination. Cyclic stress reduction, site response, CRR and magnitude corrections must be established from site-specific methods. \subsection{Accepted input ranges} \begin{itemize} \item Peak horizontal acceleration ratio amax/g: 0.001 to 2 -. \item Total overburden stress: 1 to 5000 kPa. \item Effective overburden stress: 1 to 5000 kPa. \item Depth stress-reduction factor: 0.1 to 1.5 -. \item Reference cyclic resistance ratio for Mw 7.5: 0.01 to 1.5 -. \item Magnitude scaling factor: 0.5 to 3 -. \item Confining stress correction: 0.5 to 2 -. \item Required triggering safety factor: 1 to 3 -. \end{itemize} \subsection{Reference and scope} USACE EM 1110-2-1902, Slope Stability (2003). \url{https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-1902.pdf} Limit-equilibrium principles and assumptions. Component or prescribed-plane calculations do not locate a critical slip surface. \end{document}

Engineering Calculator

Engineering Calculation Results