Micropile axial allowable load: steel, grout and ground bond

Deep Foundation, Drilled Shafts-Bearing Capacity

By Foundation Design Method Library

22 Rank #239 Views 330
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Micropile axial allowable load: steel, grout and ground bond} \subsection{Application and idealization} Bound a grout-bonded micropile compression rating by simplified axial material resistance and an average grout--ground bond limit. \subsection{Governing equations} \[ Q_{str}=(A_s f_y+A_g f_c)\cdot 1000 \] \[ Q_{bond}=\pi D L_b\tau_b \] \[ Q_{allow}=\min(Q_{str}/FS_{str},Q_{bond}/FS_{bond}) \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ As & Reinforcing steel area & m\(^{2}\) & 0.003 \\ Ag & Effective grout area & m\(^{2}\) & 0.018 \\ fy & Steel design strength input & MPa & 345 \\ fc & Grout compression strength input & MPa & 25 \\ D & Bonded grout diameter & m & 0.18 \\ Lb & Bond length in ground & m & 8 \\ tau & Ultimate ground/grout bond stress & kPa & 110 \\ FStr & Specified structural factor & - & 2 \\ FSb & Specified bond factor & - & 2.5 \\ P & Applied axial compression & kN & 250 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{Qstr} = \left(\mathrm{As}\,\mathrm{fy}+\mathrm{Ag}\,\mathrm{fc}\right)\,1000 \] \[ \mathrm{Qbond} = \pi\,D\,\mathrm{Lb}\,\tau \] \[ \mathrm{Qallow} = \operatorname{min}\left(\frac{\mathrm{Qstr}}{\mathrm{FStr}},\frac{\mathrm{Qbond}}{\mathrm{FSb}}\right) \] \[ \mathrm{FS} = \frac{\mathrm{Qallow}}{P} \] \begin{itemize} \item Gross structural compression capacity (simplified): \( \mathrm{Qstr} \). \item Ultimate grout--ground bond capacity: \( \mathrm{Qbond} \). \item Allowable axial compression load: \( \mathrm{Qallow} \). \item Allowable/demand reserve ratio: \( \mathrm{FS} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Gross structural compression capacity (simplified): 1485 kN. \item Ultimate grout--ground bond capacity: 497.62828 kN. \item Allowable axial compression load: 199.05131 kN. \item Allowable/demand reserve ratio: 0.79620524. \item Controlling resistance: Ground bond. \end{itemize} \subsection{Assumptions and interpretation} Input strengths and safety factors are project-specific; does not check buckling, structural interaction, pile settlement, group effects or code-specific factors. Do not use without geotechnical and structural verification. \subsection{Accepted input ranges} \begin{itemize} \item Reinforcing steel area: 0.00001 to 0.2 m\(^{2}\). \item Effective grout area: 0.0001 to 1 m\(^{2}\). \item Steel design strength input: 10 to 900 MPa. \item Grout compression strength input: 1 to 150 MPa. \item Bonded grout diameter: 0.05 to 2 m. \item Bond length in ground: 0.2 to 100 m. \item Ultimate ground/grout bond stress: 1 to 2000 kPa. \item Specified structural factor: 1.01 to 10 -. \item Specified bond factor: 1.01 to 10 -. \item Applied axial compression: 0.01 to 100000 kN. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results