SPT energy and overburden corrections (N60 and N1,60)

Shallow Foundation, Bearing Capacity

By Foundation Design Method Library

13 Rank #244 Views 231
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{SPT energy and overburden corrections (N60 and N1,60)} \subsection{Application and idealization} Apply common correction factors to SPT field blow count and estimate energy- and overburden-normalized penetration resistance for preliminary screening. \subsection{Governing equations} \[ N_{60}=N(C_E C_B C_R C_S) \] \[ C_E=ER/60 \] \[ C_N=min{1.7,sqrt{p_a/sigma_v^{prime}}} \] \[ (N_1)_{60}=C_N N_{60} \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ N & Measured standard penetration blows & blows/0.3m & 24 \\ ER & Hammer energy ratio & \% & 75 \\ CB & Borehole diameter correction & - & 1 \\ CR & Rod length correction & - & 0.95 \\ CS & Sampler correction & - & 1 \\ sigma\_eff & Effective overburden stress & kPa & 110 \\ Pa & Reference atmospheric pressure & kPa & 100 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{CE} = \frac{\mathrm{ER}}{60} \] \[ \mathrm{N60} = N\,\mathrm{CE}\,\mathrm{CB}\,\mathrm{CR}\,\mathrm{CS} \] \[ \mathrm{CNraw} = \sqrt{\frac{\mathrm{Pa}}{\mathrm{sigma\_eff}}} \] \[ \mathrm{CN} = \operatorname{min}\left(1.7,\mathrm{CNraw}\right) \] \[ \mathrm{N160} = \mathrm{CN}\,\mathrm{N60} \] \begin{itemize} \item Hammer correction CE: \( \mathrm{CE} \). \item Energy-normalized blows N60: \( \mathrm{N60} \). \item Overburden factor CN (capped): \( \mathrm{CN} \). \item Overburden-normalized blows (N1)60: \( \mathrm{N160} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Hammer correction CE: 1.25. \item Energy-normalized blows N60: 28.5 blows/0.3m. \item Overburden factor CN (capped): 0.95346259. \item Overburden-normalized blows (N1)60: 27.173684 blows/0.3m. \end{itemize} \subsection{Assumptions and interpretation} Check that selected correction factors, test standard, penetration depth and overburden model agree with the governing project guidance. The square-root CN relation and cap are project-dependent. \subsection{Accepted input ranges} \begin{itemize} \item Measured standard penetration blows: 1 to 200 blows/0.3m. \item Hammer energy ratio: 20 to 120 \%. \item Borehole diameter correction: 0.5 to 1.3 -. \item Rod length correction: 0.5 to 1.2 -. \item Sampler correction: 0.5 to 1.3 -. \item Effective overburden stress: 1 to 3000 kPa. \item Reference atmospheric pressure: 80 to 110 kPa. \end{itemize} \subsection{Reference and scope} FHWA Geotechnical Engineering Circular No. 6, Shallow Foundations (2002). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/010943.pdf} Shallow-foundation and serviceability background; the app is a bounded implementation of its stated idealization. \end{document}

Engineering Calculator

Engineering Calculation Results