Rankine wall thrust with groundwater and surcharge

Earth Retaining Structures, Gravity Retaining Walls

By Foundation Design Method Library

19 Rank #242 Views 258
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Rankine wall thrust with groundwater and surcharge} \subsection{Application and idealization} Integrate Rankine active effective earth pressures above and below a horizontal water table; add hydrostatic water and uniform surcharge thrust. \subsection{Governing equations} \[ K_a=\tan^2(45^\circ-\phi^{\prime}/2) \] \[ P_{soil}=K_a[\tfrac12\gamma z_w^2+\gamma z_w h_w+\tfrac12(\gamma_{sat}-\gamma_w)h_w^2] \] \[ P_{water}=\tfrac12\gamma_w h_w^2 \] \[ P_{surcharge}=K_a q_sH \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ H & Backfill height & m & 6 \\ zw & Groundwater depth below top & m & 2 \\ gamma & Moist soil unit weight & kN/m\(^{3}\) & 18 \\ gsat & Saturated soil unit weight & kN/m\(^{3}\) & 20 \\ gw & Water unit weight & kN/m\(^{3}\) & 9.81 \\ phi & Effective friction angle & deg & 30 \\ qs & Uniform backfill surcharge & kPa & 12 \\ R & Available horizontal resistance & kN/m & 320 \\ FS\_req & Required sliding FS & - & 1.5 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{zwc} = \operatorname{min}\left(\operatorname{max}\left(\mathrm{zw},0\right),H\right) \] \[ \mathrm{hw} = H-\mathrm{zwc} \] \[ \mathrm{Ka} = \operatorname{tan}\left(\frac{\left(45-\frac{\phi}{2}\right)\,\pi}{180}\right)^{2} \] \[ \mathrm{gsub} = \mathrm{gsat}-\mathrm{gw} \] \[ \mathrm{Psoil} = \mathrm{Ka}\,\left(0.5\,\gamma\,\mathrm{zwc}^{2}+\gamma\,\mathrm{zwc}\,\mathrm{hw}+0.5\,\mathrm{gsub}\,\mathrm{hw}^{2}\right) \] \[ \mathrm{Pwater} = 0.5\,\mathrm{gw}\,\mathrm{hw}^{2} \] \[ \mathrm{Psur} = \mathrm{Ka}\,\mathrm{qs}\,H \] \[ \mathrm{Ptotal} = \mathrm{Psoil}+\mathrm{Pwater}+\mathrm{Psur} \] \[ \mathrm{FS} = \frac{R}{\mathrm{Ptotal}} \] \begin{itemize} \item Effective-stress soil thrust: \( \mathrm{Psoil} \). \item Hydrostatic water thrust: \( \mathrm{Pwater} \). \item Uniform surcharge thrust: \( \mathrm{Psur} \). \item Total lateral thrust per meter wall: \( \mathrm{Ptotal} \). \item Sliding safety factor against supplied resistance: \( \mathrm{FS} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Effective-stress soil thrust: 87.173333 kN/m. \item Hydrostatic water thrust: 78.48 kN/m. \item Uniform surcharge thrust: 24 kN/m. \item Total lateral thrust per meter wall: 189.65333 kN/m. \item Sliding safety factor against supplied resistance: 1.6872891. \item Design check: Meets specified target. \end{itemize} \subsection{Assumptions and interpretation} Vertical smooth wall, level cohesionless backfill, hydrostatic horizontal water table, no drainage or seepage gradients, no seismic forces; resisting wall force must be calculated separately. \subsection{Accepted input ranges} \begin{itemize} \item Backfill height: 0.3 to 35 m. \item Groundwater depth below top: 0 to 35 m. \item Moist soil unit weight: 10 to 30 kN/m\(^{3}\). \item Saturated soil unit weight: 10 to 33 kN/m\(^{3}\). \item Water unit weight: 9 to 11 kN/m\(^{3}\). \item Effective friction angle: 0 to 50 deg. \item Uniform backfill surcharge: 0 to 500 kPa. \item Available horizontal resistance: 0.001 to 1000000 kN/m. \item Required sliding FS: 1 to 10 -. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results