Ground anchor — apparent free length from proof-test movement

Earth Retaining Structures, Anchored Walls

By Foundation Design Method Library

161 Rank #123 Views 2,806
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Ground anchor -- apparent free length from proof-test movement} \subsection{Application and idealization} Use measured elastic anchor tendon extension and steel stiffness EA to back-calculate an apparent free length for field test interpretation. \subsection{Governing equations} \[ L_{app}=\frac{\Delta u EA}{\Delta P} \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ P1 & Lower measured anchor test load & kN & 150 \\ P2 & Higher measured anchor test load & kN & 500 \\ u1 & Elastic displacement at lower load & mm & 4 \\ u2 & Elastic displacement at higher load & mm & 16 \\ A & Tendon steel cross-section & mm\(^{2}\) & 850 \\ E & Tendon steel elastic modulus & GPa & 195 \\ Lfree & Installed unbonded/free tendon length & m & 7 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{dP} = \mathrm{P2}-\mathrm{P1} \] \[ \mathrm{du} = \mathrm{u2}-\mathrm{u1} \] \[ \mathrm{Lapp} = \frac{\mathrm{du}\,E\,A}{\mathrm{dP}\,1000} \] \[ \mathrm{ratio} = \frac{\mathrm{Lapp}}{\mathrm{Lfree}} \] \begin{itemize} \item Elastic extension increment: \( \mathrm{du} \). \item Apparent free tendon length: \( \mathrm{Lapp} \). \item Apparent / installed free length ratio: \( \mathrm{ratio} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Elastic extension increment: 12 mm. \item Apparent free tendon length: 5.6828571 m. \item Apparent / installed free length ratio: 0.81183673. \item Review: Compare with project-specific proof-test criteria. \end{itemize} \subsection{Assumptions and interpretation} Use recoverable elastic extension. Seating, creep and equipment compliance must be removed before interpreting apparent free length. Compare with the project-specific proof-test specification; this calculator does not set an acceptance band. \subsection{Accepted input ranges} \begin{itemize} \item Lower measured anchor test load: 0 to 3000 kN. \item Higher measured anchor test load: 0 to 3000 kN. \item Elastic displacement at lower load: 0 to 250 mm. \item Elastic displacement at higher load: 0 to 250 mm. \item Tendon steel cross-section: 50 to 10000 mm\(^{2}\). \item Tendon steel elastic modulus: 80 to 260 GPa. \item Installed unbonded/free tendon length: 0.5 to 100 m. \end{itemize} \subsection{Reference and scope} FHWA GEC No. 4, Ground Anchors and Anchored Systems (1999). \url{https://www.fhwa.dot.gov/engineering/geotech/library_sub.cfm?keyword=020} Anchor system and test interpretation background; acceptance criteria must come from the project specification. \end{document}

Engineering Calculator

Engineering Calculation Results