Constant-head permeability test — hydraulic conductivity

Soil Improvement, Ground Improvement

By Foundation Design Method Library

119 Rank #142 Views 1,954
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Constant-head permeability test -- hydraulic conductivity} \subsection{Application and idealization} Reduce steady-state constant-head permeameter measurements with Darcy law to hydraulic conductivity. \subsection{Governing equations} \[ k=\frac{VL}{Aht} \] \[ i=\frac{h}{L} \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ V & Collected discharge volume & cm\(^{3}\) & 550 \\ L & Specimen length & cm & 15 \\ A & Specimen cross-sectional area & cm\(^{2}\) & 80 \\ h & Constant head difference & cm & 60 \\ t & Collection duration & s & 180 \\ \end{longtable} \subsection{Calculation procedure} \[ Q = \frac{V}{t} \] \[ \mathrm{igrad} = \frac{h}{L} \] \[ \mathrm{kcm} = \frac{V\,L}{A\,h\,t} \] \[ \mathrm{km} = \frac{\mathrm{kcm}}{100} \] \begin{itemize} \item Measured discharge: \( Q \). \item Hydraulic gradient: \( \mathrm{igrad} \). \item Hydraulic conductivity: \( \mathrm{kcm} \). \item Hydraulic conductivity (SI): \( \mathrm{km} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Measured discharge: 3.0555556 cm\(^{3}\)/s. \item Hydraulic gradient: 4. \item Hydraulic conductivity: 0.0095486111 cm/s. \item Hydraulic conductivity (SI): 0.000095486111 m/s. \end{itemize} \subsection{Assumptions and interpretation} Saturated, one-dimensional steady laminar flow in a representative specimen; no leakage, constant water temperature and geometry. Measure/correct temperature as required. \subsection{Accepted input ranges} \begin{itemize} \item Collected discharge volume: 0.01 to 10000000 cm\(^{3}\). \item Specimen length: 0.1 to 100 cm. \item Specimen cross-sectional area: 0.01 to 100000 cm\(^{2}\). \item Constant head difference: 0.1 to 1000 cm. \item Collection duration: 0.01 to 10000000 s. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://rosap.ntl.bts.gov/view/dot/41551} Background for soil properties, stress, strength, seepage and settlement; this tool implements only the equations stated here. \end{document}

Engineering Calculator

Engineering Calculation Results