Foundation differential settlement and angular distortion

Shallow Foundation, Settlement

By Foundation Design Method Library

217 Rank #99 Views 4,822
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Foundation differential settlement and angular distortion} \subsection{Application and idealization} Evaluate angular distortion between two supports from measured or predicted settlements and a user-selected allowable distortion. \subsection{Governing equations} \[ \Delta s=|s_B-s_A| \] \[ \beta=\frac{\Delta s/1000}{L} \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ sA & Settlement at foundation A & mm & 15 \\ sB & Settlement at foundation B & mm & 37 \\ L & Distance between foundations & m & 7 \\ betaLim & Specified angular distortion limit & - & 0.004 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{deltas} = \left|\mathrm{sB}-\mathrm{sA}\right| \] \[ \beta = \frac{\mathrm{deltas}}{1000\,L} \] \[ \mathrm{ratio} = \frac{\beta}{\mathrm{betaLim}} \] \[ \mathrm{denom} = \begin{cases}\frac{1}{\beta}&\beta>0\\\text{No differential settlement}&\text{otherwise}\end{cases} \] \begin{itemize} \item Differential settlement: \( \mathrm{deltas} \). \item Angular distortion: \( \beta \). \item Approximate L/\(\Delta\)s ratio: \( \mathrm{denom} \). \item Specified-limit utilization: \( \mathrm{ratio} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Differential settlement: 22 mm. \item Angular distortion: 0.0031428571. \item Approximate L/\(\Delta\)s ratio: 318.18182. \item Specified-limit utilization: 0.78571429. \item Serviceability screening: Within specified distortion limit. \end{itemize} \subsection{Assumptions and interpretation} Use relative vertical displacement; structural stiffness, rotation and settlement profiles are not modeled. User must specify the appropriate project- and structure-dependent limit. \subsection{Accepted input ranges} \begin{itemize} \item Settlement at foundation A: 0 to 1500 mm. \item Settlement at foundation B: 0 to 1500 mm. \item Distance between foundations: 0.1 to 200 m. \item Specified angular distortion limit: 0.0001 to 0.1 -. \end{itemize} \subsection{Reference and scope} FHWA Geotechnical Engineering Circular No. 6, Shallow Foundations (2002). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/010943.pdf} Shallow-foundation and serviceability background; the app is a bounded implementation of its stated idealization. \end{document}

Engineering Calculator

Engineering Calculation Results