Field vane shear — undrained strength from torque

Soil Improvement, Soil Phase Relations

By Foundation Design Method Library

112 Rank #147 Views 1,972
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Field vane shear -- undrained strength from torque} \subsection{Application and idealization} Derive vane shear undrained strength using cylindrical lateral and end-surface torque resistance under the common uniform-shear assumption. \subsection{Governing equations} \[ T=s_u\left(\frac{\pi D^2H}{2}+\frac{\pi D^3}{6}\right) \] \[ s_{u,corr}=\mu s_u \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ T & Measured peak torque & kN\(\cdot\)m & 0.12 \\ D & Vane diameter & m & 0.075 \\ H & Vane height & m & 0.15 \\ mu & Vane correction factor & - & 0.85 \\ \end{longtable} \subsection{Calculation procedure} \[ G = \frac{\pi\,D^{2}\,H}{2}+\frac{\pi\,D^{3}}{6} \] \[ s_u = \frac{T}{G} \] \[ \mathrm{corr} = s_u\,\mathrm{mu} \] \begin{itemize} \item Uncorrected undrained shear strength: \( s_u \). \item Corrected interpretation: \( \mathrm{corr} \). \item Vane geometric torque factor: \( G \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Uncorrected undrained shear strength: 77.606982 kPa. \item Corrected interpretation: 65.965935 kPa. \item Vane geometric torque factor: 0.0015462526 m\(^{3}\). \end{itemize} \subsection{Assumptions and interpretation} Uniform mobilized undrained strength on vane boundaries; correction factor selected from applicable project practice. Rod friction, anisotropy, rate effects, remolding and sensitivity need separate treatment. \subsection{Accepted input ranges} \begin{itemize} \item Measured peak torque: 0.00001 to 100 kN\(\cdot\)m. \item Vane diameter: 0.02 to 0.8 m. \item Vane height: 0.03 to 1 m. \item Vane correction factor: 0.2 to 1.5 -. \end{itemize} \subsection{Reference and scope} FHWA Ground Improvement guidance and GEC No. 13 reference manuals. \url{https://www.fhwa.dot.gov/engineering/geotech/improvement/index.cfm} Ground modification concepts; the app covers the listed mechanism rather than a complete improvement design. \end{document}

Engineering Calculator

Engineering Calculation Results