Driven pile — two-layer clay adhesion and toe capacity

Deep Foundation, Drive Piles-Bearing Capacity

By Foundation Design Method Library

182 Rank #110 Views 3,895
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Driven pile -- two-layer clay adhesion and toe capacity} \subsection{Application and idealization} Compute layer-by-layer total-stress clay adhesion and toe capacity of a cylindrical pile with distinct undrained strengths and adhesion factors. \subsection{Governing equations} \[ Q_{su}=\pi D(\alpha_1 s_{u1}L_1+\alpha_2 s_{u2}L_2) \] \[ Q_{bu}=N_c s_{u2}\frac{\pi D^2}{4} \] \[ Q_{ult}=Q_{su}+Q_{bu} \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ D & Pile diameter & m & 0.45 \\ L1 & Upper cohesive layer pile contact & m & 6 \\ L2 & Lower cohesive layer pile contact & m & 8 \\ su1 & Upper layer undrained shear strength & kPa & 42 \\ su2 & Lower layer undrained shear strength & kPa & 85 \\ alpha1 & Upper layer adhesion factor & - & 0.7 \\ alpha2 & Lower layer adhesion factor & - & 0.5 \\ Nc & Selected undrained toe bearing factor & - & 9 \\ P & Applied axial compression load & kN & 900 \\ FSreq & Required factor of safety & - & 2.5 \\ \end{longtable} \subsection{Calculation procedure} \[ A = \frac{\pi\,D^{2}}{4} \] \[ \mathrm{Q1} = \pi\,D\,\mathrm{L1}\,\mathrm{alpha1}\,\mathrm{su1} \] \[ \mathrm{Q2} = \pi\,D\,\mathrm{L2}\,\mathrm{alpha2}\,\mathrm{su2} \] \[ \mathrm{Qtoe} = \mathrm{Nc}\,\mathrm{su2}\,A \] \[ \mathrm{Qu} = \mathrm{Q1}+\mathrm{Q2}+\mathrm{Qtoe} \] \[ \mathrm{Qa} = \frac{\mathrm{Qu}}{\mathrm{FSreq}} \] \[ \mathrm{FS} = \frac{\mathrm{Qu}}{P} \] \begin{itemize} \item Upper-layer shaft resistance: \( \mathrm{Q1} \). \item Lower-layer shaft resistance: \( \mathrm{Q2} \). \item Toe resistance: \( \mathrm{Qtoe} \). \item Total ultimate axial resistance: \( \mathrm{Qu} \). \item Allowable axial capacity: \( \mathrm{Qa} \). \item Computed ultimate resistance / load: \( \mathrm{FS} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Upper-layer shaft resistance: 249.37962 kN. \item Lower-layer shaft resistance: 480.66368 kN. \item Toe resistance: 121.66799 kN. \item Total ultimate axial resistance: 851.71129 kN. \item Allowable axial capacity: 340.68452 kN. \item Computed ultimate resistance / load: 0.94634588. \item Capacity screening: Does not meet target. \end{itemize} \subsection{Assumptions and interpretation} Design \(\alpha\)1, \(\alpha\)2 and Nc must be selected for the site and installation method. Does not include group effects, downdrag, negative shaft friction, cyclic effects, or settlement. \subsection{Accepted input ranges} \begin{itemize} \item Pile diameter: 0.1 to 3 m. \item Upper cohesive layer pile contact: 0.1 to 75 m. \item Lower cohesive layer pile contact: 0.1 to 75 m. \item Upper layer undrained shear strength: 1 to 500 kPa. \item Lower layer undrained shear strength: 1 to 700 kPa. \item Upper layer adhesion factor: 0.01 to 1 -. \item Lower layer adhesion factor: 0.01 to 1 -. \item Selected undrained toe bearing factor: 1 to 15 -. \item Applied axial compression load: 1 to 1000000 kN. \item Required factor of safety: 1 to 10 -. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results