Sheet-pile wall — section modulus and bending-stress check

Earth Retaining Structures, Cantilever Retaining Walls

By Foundation Design Method Library

175 Rank #113 Views 3,568
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Sheet-pile wall -- section modulus and bending-stress check} \subsection{Application and idealization} Check a supplied sheet-pile section against a separately calculated bending moment demand, without performing a soil-structure embedment analysis. \subsection{Governing equations} \[ \sigma_b=\frac{M}{Z}=\frac{1000M_{kN\cdot m/m}}{Z_{cm^3/m}}\text{ MPa} \] \[ Z_{req}=1000M/(f_y/FS_{req}) \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ M & Factored design bending moment per wall meter & kN\(\cdot\)m/m & 125 \\ Z & Sheet-pile section modulus per wall meter & cm\(^{3}\)/m & 1450 \\ fy & Specified steel yield strength & MPa & 355 \\ FSreq & Specified stress safety factor & - & 1.5 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{sig} = \frac{1000\,M}{Z} \] \[ \mathrm{allow} = \frac{\mathrm{fy}}{\mathrm{FSreq}} \] \[ U = \frac{\mathrm{sig}}{\mathrm{allow}} \] \[ \mathrm{Zreq} = \frac{1000\,M}{\mathrm{allow}} \] \begin{itemize} \item Calculated extreme-fiber bending stress: \( \mathrm{sig} \). \item User-specified allowable stress: \( \mathrm{allow} \). \item Required section modulus: \( \mathrm{Zreq} \). \item Bending stress utilization: \( U \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Calculated extreme-fiber bending stress: 86.206897 MPa. \item User-specified allowable stress: 236.66667 MPa. \item Required section modulus: 528.16901 cm\(^{3}\)/m. \item Bending stress utilization: 0.36425449. \item Structural screening: Within specified stress target. \end{itemize} \subsection{Assumptions and interpretation} Moment per wall meter and section modulus per wall meter use consistent units. Account separately for corrosion, section reductions, lateral support, serviceability, global stability and governing structural standards. \subsection{Accepted input ranges} \begin{itemize} \item Factored design bending moment per wall meter: 0.01 to 1000000 kN\(\cdot\)m/m. \item Sheet-pile section modulus per wall meter: 1 to 1000000 cm\(^{3}\)/m. \item Specified steel yield strength: 20 to 1200 MPa. \item Specified stress safety factor: 1 to 5 -. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results