Soil nail — tributary tensile demand and pullout capacity

Earth Retaining Structures, Anchored Walls

By Foundation Design Method Library

168 Rank #118 Views 2,694
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,longtable,hyperref} \begin{document} \section{Soil nail -- tributary tensile demand and pullout capacity} \subsection{Application and idealization} Combine an indicative Rankine pressure tributary-area nail demand with grout-ground pullout resistance to screen nail spacing and bond length. \subsection{Governing equations} \[ T_d=K_a(\gamma z+q)S_hS_v \] \[ Q_{pullout}=\pi D L_b\tau_b \] \[ FS=Q_{pullout}/T_d \] \subsection{Inputs, symbols and units} \begin{longtable}{p{0.16\linewidth}p{0.42\linewidth}p{0.12\linewidth}p{0.18\linewidth}} Symbol & Meaning & Unit & Default \\ z & Depth of nail head below wall top & m & 4 \\ gamma & Retained soil unit weight & kN/m\(^{3}\) & 19 \\ phi & Soil effective friction angle & degrees & 30 \\ q & Uniform surface surcharge & kPa & 12 \\ Sh & Horizontal soil-nail spacing & m & 1.5 \\ Sv & Vertical soil-nail spacing & m & 1.5 \\ D & Grouted-hole diameter & m & 0.15 \\ Lb & Effective nail length in resisting zone & m & 5 \\ tau & Selected ultimate grout-ground bond stress & kPa & 95 \\ FSreq & Specified pullout safety factor & - & 2 \\ \end{longtable} \subsection{Calculation procedure} \[ \mathrm{Ka} = \operatorname{tan}\left(\frac{\left(45-\frac{\phi}{2}\right)\,\pi}{180}\right)^{2} \] \[ \mathrm{pa} = \mathrm{Ka}\,\left(\gamma\,z+q\right) \] \[ \mathrm{Td} = \mathrm{pa}\,\mathrm{Sh}\,\mathrm{Sv} \] \[ \mathrm{Qu} = \pi\,D\,\mathrm{Lb}\,\tau \] \[ \mathrm{Qa} = \frac{\mathrm{Qu}}{\mathrm{FSreq}} \] \[ \mathrm{FS} = \frac{\mathrm{Qu}}{\mathrm{Td}} \] \begin{itemize} \item Active lateral pressure at nail row: \( \mathrm{pa} \). \item Approximate tributary nail tension: \( \mathrm{Td} \). \item Nominal nail pullout resistance: \( \mathrm{Qu} \). \item Allowable nail pullout resistance: \( \mathrm{Qa} \). \item Pullout factor of safety: \( \mathrm{FS} \). \end{itemize} \subsection{Worked example using default inputs} \begin{itemize} \item Active lateral pressure at nail row: 29.333333 kPa. \item Approximate tributary nail tension: 66 kN/nail. \item Nominal nail pullout resistance: 223.83848 kN/nail. \item Allowable nail pullout resistance: 111.91924 kN/nail. \item Pullout factor of safety: 3.3914921. \item Screening check: Meets specified pullout target. \end{itemize} \subsection{Assumptions and interpretation} This is NOT a full soil-nail wall design: passive reinforcement behavior, internal and global stability, critical surfaces, corrosion, facing and structural nail tension require separate checks. \(\tau\) must be validated by testing. \subsection{Accepted input ranges} \begin{itemize} \item Depth of nail head below wall top: 0.1 to 30 m. \item Retained soil unit weight: 5 to 35 kN/m\(^{3}\). \item Soil effective friction angle: 0 to 50 degrees. \item Uniform surface surcharge: 0 to 1000 kPa. \item Horizontal soil-nail spacing: 0.3 to 5 m. \item Vertical soil-nail spacing: 0.3 to 5 m. \item Grouted-hole diameter: 0.05 to 0.8 m. \item Effective nail length in resisting zone: 0.2 to 30 m. \item Selected ultimate grout-ground bond stress: 1 to 3000 kPa. \item Specified pullout safety factor: 1 to 10 -. \end{itemize} \subsection{Reference and scope} FHWA NHI-06-089, Soils and Foundations Reference Manual, Volume II (2006). \url{https://rosap.ntl.bts.gov/view/dot/53656} Foundation and retaining-system background. Project-specific factors and complete design checks remain separate. \end{document}

Engineering Calculator

Engineering Calculation Results