Anisotropic soil — conductivity normal to an inclined plane

Groundwater & Seepage, Anisotropic Flow

By Foundation Design Method Library

105 Rank #153 Views 1,999
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Anisotropic soil - conductivity normal to an inclined plane} \subsection{Purpose} Resolve a diagonal conductivity tensor onto a specified normal direction for a normal hydraulic gradient. \subsection{Governing equations} \[ k_n=k_h\cos^2\theta+k_v\sin^2\theta \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Horizontal principal conductivity} ($\mathtt{kh}$): m/day. Default 10. \item \textbf{Vertical principal conductivity} ($\mathtt{kv}$): m/day. Default 1. \item \textbf{Plane-normal angle from horizontal principal axis} ($\mathtt{theta}$): degrees. Default 45. \item \textbf{Head-loss gradient along the plane normal} ($\mathtt{gradient}$): -. Default 0.1. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Normal hydraulic conductivity: m/day. \item Signed normal Darcy flux: m/day. \item Principal anisotropy ratio: -. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Normal hydraulic conductivity: 5.5 m/day. \item Signed normal Darcy flux: 0.55 m/day. \item Principal anisotropy ratio: 10 -. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{kh}=10$: m/day. \item $\mathtt{kv}=1$: m/day. \item $\mathtt{theta}=45$: degrees. \item $\mathtt{gradient}=0.1$: -. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Normal hydraulic conductivity: 5.5. \item Signed normal Darcy flux: 0.55. \item Principal anisotropy ratio: 10. \end{itemize} \subsection{Assumptions and limits} The total flow vector need not be parallel to the gradient in an anisotropic medium. This output is the normal flux component, not an equivalent layered-medium harmonic average. \subsection{Reference} USACE EM 1110-2-1901, Seepage Analysis and Control for Dams. \url{https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-1901.pdf} Head, anisotropy, seepage and drain/filter concepts; project-specific filter criteria must be selected. \end{document}

Engineering Calculator

Engineering Calculation Results