Symmetric batter piles — axial-force equilibrium

Deep Foundation, Pile Group Loads

By Foundation Design Method Library

105 Rank #156 Views 2,144
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Symmetric batter piles - axial-force equilibrium} \subsection{Purpose} Resolve vertical and horizontal cap forces into axial forces in two symmetrically inclined piles. \subsection{Governing equations} \[ N_\pm=\frac12\left(\frac V{\cos\theta}\pm\frac H{\sin\theta}\right) \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Downward cap force} ($\mathtt{V}$): kN. Default 1000. \item \textbf{Horizontal cap force} ($\mathtt{H}$): kN. Default 100. \item \textbf{Pile inclination from vertical} ($\mathtt{theta}$): degrees. Default 15. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Axial force in positive-rake pile: kN. \item Axial force in negative-rake pile: kN. \item Smallest axial compression: kN. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Axial force in positive-rake pile: 710.823255 kN. \item Axial force in negative-rake pile: 324.452925 kN. \item Smallest axial compression: 324.452925 kN. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{V}=866.025404$: kN. \item $\mathtt{H}=0$: kN. \item $\mathtt{theta}=30$: degrees. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Axial force in positive-rake pile: 500. \item Axial force in negative-rake pile: 500. \end{itemize} \subsection{Assumptions and limits} Pin-jointed axial-force-only idealization with equal and opposite rake. Bending, soil lateral resistance and cap flexibility are excluded. Negative force means a tension load path is required. \subsection{Reference} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06088.pdf} Soil phase relations, stress transformations, laboratory data reduction, soil classification and consolidation. Equations are implemented independently; this application is not an FHWA product. \end{document}

Engineering Calculator

Engineering Calculation Results