Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Two-column combined footing - resultant and uniform-contact plan} \subsection{Purpose} Lay out a rectangular combined footing whose plan centroid coincides with the resultant of two vertical column loads. \subsection{Governing equations} \[ x_R=a+\frac{P_2S}{P_1+P_2},\quad L=2x_R,\quad B=\frac{P_1+P_2}{q_aL} \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Near-column vertical load} ($\mathtt{P1}$): kN. Default 600. \item \textbf{Far-column vertical load} ($\mathtt{P2}$): kN. Default 1000. \item \textbf{Near-column offset from footing edge} ($\mathtt{a}$): m. Default 0.5. \item \textbf{Column center spacing} ($\mathtt{S}$): m. Default 4. \item \textbf{Selected allowable contact pressure} ($\mathtt{qa}$): kPa. Default 200. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Resultant location from near edge: m. \item Length for coincident area centroid: m. \item Minimum width using supplied pressure: m. \item Far-edge overhang: m. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Resultant location from near edge: 3 m. \item Length for coincident area centroid: 6 m. \item Minimum width using supplied pressure: 1.33333333 m. \item Far-edge overhang: 1.5 m. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{P1}=500$: kN. \item $\mathtt{P2}=500$: kN. \item $\mathtt{a}=1$: m. \item $\mathtt{S}=4$: m. \item $\mathtt{qa}=100$: kPa. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Resultant location from near edge: 3. \item Length for coincident area centroid: 6. \item Minimum width using supplied pressure: 1.66666667. \item Far-edge overhang: 1. \end{itemize} \subsection{Assumptions and limits} Footing self-weight, moments, settlement and structural design are excluded. The width is based on a separately selected contact-pressure limit. The implied rectangle must contain both columns. \subsection{Reference} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06088.pdf} Soil phase relations, stress transformations, laboratory data reduction, soil classification and consolidation. Equations are implemented independently; this application is not an FHWA product. \end{document}

Engineering Calculator

Engineering Calculation Results