Cyclic triaxial test — cyclic stress ratio from force amplitude

Geotechnical Earthquake Engineering, Cyclic Soil Tests

By Foundation Design Method Library

101 Rank #160 Views 1,227
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Cyclic triaxial test - cyclic stress ratio from force amplitude} \subsection{Purpose} Normalize a cyclic triaxial force amplitude by the effective isotropic consolidation pressure. \subsection{Governing equations} \[ CSR_{TX}=\frac{\sigma_{d,cyc}}{2\sigma'_{3c}},\quad \sigma_{d,cyc}=P_{amp}/A \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Cyclic deviator force amplitude} ($\mathtt{Pamp}$): N. Default 100. \item \textbf{Corrected specimen diameter} ($\mathtt{D}$): mm. Default 50. \item \textbf{Effective consolidation pressure} ($\mathtt{s3c}$): kPa. Default 100. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Cyclic deviator stress amplitude: kPa. \item Triaxial cyclic stress ratio: -. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Cyclic deviator stress amplitude: 50.9295818 kPa. \item Triaxial cyclic stress ratio: 0.254647909 -. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{Pamp}=62.8318531$: N. \item $\mathtt{D}=40$: mm. \item $\mathtt{s3c}=100$: kPa. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Cyclic deviator stress amplitude: 50. \item Triaxial cyclic stress ratio: 0.25. \end{itemize} \subsection{Assumptions and limits} Use single amplitude, not peak-to-peak force. This is a test loading descriptor, not an earthquake liquefaction factor of safety; field conversion and failure criteria are separate. \subsection{Reference} FHWA-NHI-11-032, Seismic Design - Geotechnical Features. \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi11032/nhi11032.pdf} Background on wave propagation, site response and displacement-based seismic geotechnics; simple oscillator tools implement their displayed mechanics only. \end{document}

Engineering Calculator

Engineering Calculation Results