Unconfined aquifer — Dupuit steady pumping water table

Groundwater & Seepage, Pumping & Dewatering

By Foundation Design Method Library

97 Rank #169 Views 1,464
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Unconfined aquifer - Dupuit steady pumping water table} \subsection{Purpose} Screen the steady unconfined water-table depression around a pumping well using the Dupuit approximation. \subsection{Governing equations} \[ h(r)^2=H^2-\frac{Q}{\pi k}\ln\frac Rr \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Steady pumping rate} ($\mathtt{Q}$): m3/day. Default 200. \item \textbf{Hydraulic conductivity} ($\mathtt{k}$): m/day. Default 10. \item \textbf{Saturated thickness at outer boundary} ($\mathtt{H}$): m. Default 20. \item \textbf{Outer constant-head radius} ($\mathtt{R}$): m. Default 500. \item \textbf{Observation radius} ($\mathtt{r}$): m. Default 10. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Saturated thickness at observation radius: m. \item Water-table drawdown: m. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Saturated thickness at observation radius: 19.3673769 m. \item Water-table drawdown: 0.632623098 m. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{Q}=31.4159265$: m3/day. \item $\mathtt{k}=1$: m/day. \item $\mathtt{H}=5$: m. \item $\mathtt{R}=27.1828183$: m. \item $\mathtt{r}=10$: m. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Saturated thickness at observation radius: 3.87298335. \item Water-table drawdown: 1.12701665. \end{itemize} \subsection{Assumptions and limits} Horizontal flow, small water-table slopes, flat impermeable base and full penetration. Near-well vertical flow and delayed yield are excluded. A negative h-squared means the imposed pumping case cannot remain saturated. \subsection{Reference} Lohman (1972), Ground-Water Hydraulics, USGS Professional Paper 708. \url{https://pubs.usgs.gov/publication/pp708} Darcy flow, steady pumping and late-time aquifer-test equations. Each app states its own boundary conditions. \end{document}

Engineering Calculator

Engineering Calculation Results