Geocomposite drain — in-plane transmissivity sizing

Groundwater & Seepage, Filters & Geosynthetics

By Foundation Design Method Library

105 Rank #154 Views 1,948
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Geocomposite drain - in-plane transmissivity sizing} \subsection{Purpose} Check a geocomposite drain against an in-plane flow requirement using a supplied long-term reduction factor. \subsection{Governing equations} \[ Q_d=\frac{\theta iW}{RF},\quad \theta_{req}=\frac{Q_{req}RF}{iW} \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Measured in-plane transmissivity} ($\mathtt{theta}$): m2/s. Default 0.001. \item \textbf{Hydraulic gradient} ($\mathtt{i}$): -. Default 0.1. \item \textbf{Drain width} ($\mathtt{W}$): m. Default 2. \item \textbf{Required flow} ($\mathtt{Qreq}$): L/s. Default 0.1. \item \textbf{Combined reduction factor} ($\mathtt{RF}$): -. Default 4. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Reduced in-plane discharge: L/s. \item Required laboratory transmissivity: m2/s. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Reduced in-plane discharge: 0.05 L/s. \item Required laboratory transmissivity: 0.002 m2/s. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{theta}=0.001$: m2/s. \item $\mathtt{i}=0.1$: -. \item $\mathtt{W}=2$: m. \item $\mathtt{Qreq}=0.1$: L/s. \item $\mathtt{RF}=4$: -. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Reduced in-plane discharge: 0.05. \item Required laboratory transmissivity: 0.002. \end{itemize} \subsection{Assumptions and limits} Measured transmissivity must represent the confining stress, boundary surfaces and gradient of the installation. Creep, intrusion and clogging factors are selected separately. \subsection{Reference} USACE EM 1110-2-1901, Seepage Analysis and Control for Dams. \url{https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-1901.pdf} Head, anisotropy, seepage and drain/filter concepts; project-specific filter criteria must be selected. \end{document}

Engineering Calculator

Engineering Calculation Results