Energy geotechnics — steady heat flow through two soil layers

Earthworks & Construction, Thermal Ground Engineering

By Foundation Design Method Library

48 Rank #206 Views 948
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Energy geotechnics - steady heat flow through two soil layers} \subsection{Purpose} Solve the one-dimensional steady conduction balance through two soil layers in series. \subsection{Governing equations} \[ R_T=\frac{H_1}{k_1}+\frac{H_2}{k_2},\quad q_T=\frac{T_{top}-T_{bottom}}{R_T} \] \subsection{Inputs and units} \begin{itemize} \item \textbf{First layer thickness} ($\mathtt{H1}$): m. Default 1. \item \textbf{First layer thermal conductivity} ($\mathtt{k1}$): W/(m K). Default 1. \item \textbf{Second layer thickness} ($\mathtt{H2}$): m. Default 2. \item \textbf{Second layer thermal conductivity} ($\mathtt{k2}$): W/(m K). Default 2. \item \textbf{Temperature at top boundary} ($\mathtt{Ttop}$): degreesC. Default 20. \item \textbf{Temperature at bottom boundary} ($\mathtt{Tbottom}$): degreesC. Default 10. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Total thermal resistance per area: m2 K/W. \item Downward-positive conductive heat flux: W/m2. \item Layer-interface temperature: degreesC. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Total thermal resistance per area: 2 m2 K/W. \item Downward-positive conductive heat flux: 5 W/m2. \item Layer-interface temperature: 15 degreesC. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{H1}=1$: m. \item $\mathtt{k1}=1$: W/(m K). \item $\mathtt{H2}=2$: m. \item $\mathtt{k2}=2$: W/(m K). \item $\mathtt{Ttop}=20$: degreesC. \item $\mathtt{Tbottom}=10$: degreesC. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Total thermal resistance per area: 2. \item Downward-positive conductive heat flux: 5. \item Layer-interface temperature: 15. \end{itemize} \subsection{Assumptions and limits} Constant conductivities, perfect interface contact and fixed boundary temperatures. Groundwater advection, seasonal storage, latent heat, freezing and moisture-dependent conductivity are excluded. \subsection{Reference} ASHRAE Handbook - Heat, Air, and Moisture Control, Fundamentals. \url{https://handbook.ashrae.org/handbooks/F17/SI/f17_ch25/f17_ch25_si.aspx} Fourier conduction and layer thermal resistances. Applied here to two soil layers with independently selected constant conductivities. \end{document}

Engineering Calculator

Engineering Calculation Results