Parallel drains — Dupuit discharge through an unconfined strip

Groundwater & Seepage, Drainage

By Foundation Design Method Library

127 Rank #139 Views 2,224
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Parallel drains - Dupuit discharge through an unconfined strip} \subsection{Purpose} Estimate steady unconfined seepage between two parallel constant-head boundaries with a horizontal impermeable base. \subsection{Governing equations} \[ q=\frac{k(h_1^2-h_2^2)}{2L} \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Hydraulic conductivity} ($\mathtt{k}$): m/day. Default 2. \item \textbf{Upstream water depth above impermeable base} ($\mathtt{h1}$): m. Default 8. \item \textbf{Downstream drain depth of water} ($\mathtt{h2}$): m. Default 3. \item \textbf{Distance between head boundaries} ($\mathtt{L}$): m. Default 40. \item \textbf{Out-of-plane drained width} ($\mathtt{W}$): m. Default 100. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Discharge per unit width: m3/day/m. \item Total flow for supplied width: m3/day. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Discharge per unit width: 1.375 m3/day/m. \item Total flow for supplied width: 137.5 m3/day. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{k}=2$: m/day. \item $\mathtt{h1}=5$: m. \item $\mathtt{h2}=3$: m. \item $\mathtt{L}=8$: m. \item $\mathtt{W}=10$: m. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Discharge per unit width: 2. \item Total flow for supplied width: 20. \end{itemize} \subsection{Assumptions and limits} Dupuit horizontal-flow approximation; no recharge. h1 and h2 are saturated thicknesses above the same base, not elevations from different datums. \subsection{Reference} Lohman (1972), Ground-Water Hydraulics, USGS Professional Paper 708. \url{https://pubs.usgs.gov/publication/pp708} Darcy flow, steady pumping and late-time aquifer-test equations. Each app states its own boundary conditions. \end{document}

Engineering Calculator

Engineering Calculation Results