Rock point-load test — size-corrected strength index

Rock Engineering, Rock Laboratory Tests

By Foundation Design Method Library

37 Rank #220 Views 853
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Rock point-load test - size-corrected strength index} \subsection{Purpose} Reduce a valid point-load failure measurement to the reference 50-mm index and an optional calibrated UCS estimate. \subsection{Governing equations} \[ I_s=\frac P{D_e^2},\quad I_{s(50)}=\left(\frac{D_e}{50\,mm}\right)^{0.45}I_s \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Failure load} ($\mathtt{P}$): kN. Default 5. \item \textbf{Equivalent core diameter} ($\mathtt{De}$): mm. Default 50. \item \textbf{Project-calibrated UCS to Is50 ratio} ($\mathtt{Cucs}$): -. Default 24. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Uncorrected point-load index: MPa. \item Size correction factor: -. \item Size-corrected Is50: MPa. \item UCS estimated using supplied ratio: MPa. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Uncorrected point-load index: 2 MPa. \item Size correction factor: 1 -. \item Size-corrected Is50: 2 MPa. \item UCS estimated using supplied ratio: 48 MPa. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{P}=5$: kN. \item $\mathtt{De}=50$: mm. \item $\mathtt{Cucs}=24$: -. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Uncorrected point-load index: 2. \item Size correction factor: 1. \item Size-corrected Is50: 2. \item UCS estimated using supplied ratio: 48. \end{itemize} \subsection{Assumptions and limits} Equivalent diameter must follow the specimen geometry definition. The default UCS ratio is illustrative; calibrate to the rock type, orientation, moisture and a paired UCS dataset. \subsection{Reference} Hoek, Practical Rock Engineering (2023). \url{https://static.rocscience.cloud/assets/resources/learning/hoek/Practical-Rock-Engineering-E.Hoek-2023.pdf} Rock testing, discontinuity strength, rock mass characterization and elastic excavation mechanics. \end{document}

Engineering Calculator

Engineering Calculation Results