Shrinkage test — shrinkage limit by volume balance

Laboratory & Site Characterization, Index Tests

By Foundation Design Method Library

110 Rank #149 Views 1,546
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Shrinkage test - shrinkage limit by volume balance} \subsection{Purpose} Apply water and volume conservation to estimate shrinkage limit from initial and dry specimen measurements. \subsection{Governing equations} \[ w_s=100\frac{(M_{wet}-M_d)-\rho_w(V_i-V_d)}{M_d} \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Initial wet specimen mass} ($\mathtt{Mwet}$): g. Default 30. \item \textbf{Oven-dry specimen mass} ($\mathtt{Md}$): g. Default 20. \item \textbf{Initial specimen volume} ($\mathtt{Vi}$): cm3. Default 18. \item \textbf{Dry specimen volume} ($\mathtt{Vd}$): cm3. Default 14. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Shrinkage limit: \%. \item Volumetric shrinkage: \%. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Shrinkage limit: 30 \%. \item Volumetric shrinkage: 28.5714286 \%. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{Mwet}=30$: g. \item $\mathtt{Md}=20$: g. \item $\mathtt{Vi}=18$: cm3. \item $\mathtt{Vd}=14$: cm3. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Shrinkage limit: 30. \item Volumetric shrinkage: 28.5714286. \end{itemize} \subsection{Assumptions and limits} Water density is 1 g/cm3. The dry specimen volume must come from an appropriate non-destructive volume measurement. Negative shrinkage limits indicate inconsistent data. \subsection{Reference} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06088.pdf} Soil phase relations, stress transformations, laboratory data reduction, soil classification and consolidation. Equations are implemented independently; this application is not an FHWA product. \end{document}

Engineering Calculator

Engineering Calculation Results