Below-grade slab — self-weight thickness against uplift

Shallow Foundation, Uplift & Buoyancy

By Foundation Design Method Library

47 Rank #209 Views 1,102
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Below-grade slab - self-weight thickness against uplift} \subsection{Purpose} Determine the slab self-weight required to balance a specified hydrostatic uplift pressure and safety factor. \subsection{Governing equations} \[ t_{req}=\max\left(0,\frac{FS\,\gamma_wh_w-q_{dead}}{\gamma_c}\right) \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Design water head above slab underside} ($\mathtt{hw}$): m. Default 2. \item \textbf{Concrete unit weight} ($\mathtt{gammaC}$): kN/m3. Default 24. \item \textbf{Other reliable permanent downward pressure} ($\mathtt{qdead}$): kPa. Default 10. \item \textbf{Selected uplift factor of safety} ($\mathtt{FS}$): -. Default 1.2. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Hydrostatic uplift pressure: kPa. \item Required self-weight slab thickness: m. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Hydrostatic uplift pressure: 19.6133 kPa. \item Required self-weight slab thickness: 0.563998333 m. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{hw}=1$: m. \item $\mathtt{gammaC}=20$: kN/m3. \item $\mathtt{qdead}=0$: kPa. \item $\mathtt{FS}=1$: -. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Hydrostatic uplift pressure: 9.80665. \item Required self-weight slab thickness: 0.4903325. \end{itemize} \subsection{Assumptions and limits} Head is measured above the slab underside and is held fixed. Structural bending, cracking, drains, anchors, load factors and beneficial permanent-load reliability need separate assessment. \subsection{Reference} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06088.pdf} Soil phase relations, stress transformations, laboratory data reduction, soil classification and consolidation. Equations are implemented independently; this application is not an FHWA product. \end{document}

Engineering Calculator

Engineering Calculation Results