Uniform infinite strip — vertical stress beneath centerline

Shallow Foundation, Stress Distribution

By Foundation Design Method Library

41 Rank #216 Views 460
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Uniform infinite strip - vertical stress beneath centerline} \subsection{Purpose} Calculate elastic vertical stress on the centerline below an infinitely long uniformly loaded strip. \subsection{Governing equations} \[ \Delta\sigma_z=\frac{2q}{\pi}\left[\tan^{-1}m+\frac{m}{1+m^2}\right],\quad m=\frac B{2z} \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Strip load width} ($\mathtt{B}$): m. Default 2. \item \textbf{Depth beneath centerline} ($\mathtt{z}$): m. Default 2. \item \textbf{Uniform strip pressure} ($\mathtt{q}$): kPa. Default 100. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Centerline stress influence factor: -. \item Vertical stress increase: kPa. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Centerline stress influence factor: 0.549815144 -. \item Vertical stress increase: 54.9815144 kPa. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{B}=2$: m. \item $\mathtt{z}=1$: m. \item $\mathtt{q}=100$: kPa. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Centerline stress influence factor: 0.818309886. \item Vertical stress increase: 81.8309886. \end{itemize} \subsection{Assumptions and limits} Surface strip is flexible and infinitely long. Finite rectangles, embedded foundations and layered stiffness require other solutions. \subsection{Reference} FHWA-HRT-15-080, Synthesis and Evaluation of the Service Limit State of Engineered Fills for Bridge Support, chapter 3. \url{https://www.fhwa.dot.gov/publications/research/infrastructure/structures/bridge/15080/003.cfm} Elastic half-space stress-distribution assumptions and the distinction between Boussinesq and Westergaard media. \end{document}

Engineering Calculator

Engineering Calculation Results