Confined aquifer — Thiem steady pumping drawdown

Groundwater & Seepage, Pumping & Dewatering

By Foundation Design Method Library

133 Rank #134 Views 1,656
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Confined aquifer - Thiem steady pumping drawdown} \subsection{Purpose} Estimate steady confined-aquifer drawdown around a fully penetrating pumping well. \subsection{Governing equations} \[ s(r)=\frac{Q}{2\pi T}\ln\frac Rr \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Steady pumping rate} ($\mathtt{Q}$): m3/day. Default 500. \item \textbf{Aquifer transmissivity} ($\mathtt{T}$): m2/day. Default 100. \item \textbf{Constant-head boundary radius} ($\mathtt{R}$): m. Default 1000. \item \textbf{Observation radius} ($\mathtt{r}$): m. Default 10. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Steady drawdown at observation radius: m. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Steady drawdown at observation radius: 3.66467799 m. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{Q}=628.318531$: m3/day. \item $\mathtt{T}=100$: m2/day. \item $\mathtt{R}=27.1828183$: m. \item $\mathtt{r}=10$: m. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Steady drawdown at observation radius: 1. \end{itemize} \subsection{Assumptions and limits} Homogeneous aquifer, horizontal radial flow and an actual or justified constant-head boundary at R. This steady formula cannot predict the transient radius of influence. \subsection{Reference} Lohman (1972), Ground-Water Hydraulics, USGS Professional Paper 708. \url{https://pubs.usgs.gov/publication/pp708} Darcy flow, steady pumping and late-time aquifer-test equations. Each app states its own boundary conditions. \end{document}

Engineering Calculator

Engineering Calculation Results