Confined pumping test — transmissivity from two observation wells

Groundwater & Seepage, Aquifer Tests

By Foundation Design Method Library

85 Rank #181 Views 995
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Confined pumping test - transmissivity from two observation wells} \subsection{Purpose} Infer transmissivity from two simultaneous observation-well drawdowns at steady pumping conditions. \subsection{Governing equations} \[ T=\frac{Q\ln(r_2/r_1)}{2\pi(s_1-s_2)},\quad k=T/b \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Steady well discharge} ($\mathtt{Q}$): m3/day. Default 500. \item \textbf{Near observation radius} ($\mathtt{r1}$): m. Default 10. \item \textbf{Far observation radius} ($\mathtt{r2}$): m. Default 100. \item \textbf{Near-well steady drawdown} ($\mathtt{s1}$): m. Default 5. \item \textbf{Far-well steady drawdown} ($\mathtt{s2}$): m. Default 3. \item \textbf{Aquifer saturated thickness} ($\mathtt{b}$): m. Default 20. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Fitted transmissivity: m2/day. \item Hydraulic conductivity: m/day. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Fitted transmissivity: 91.6169499 m2/day. \item Hydraulic conductivity: 4.58084749 m/day. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{Q}=628.318531$: m3/day. \item $\mathtt{r1}=10$: m. \item $\mathtt{r2}=27.1828183$: m. \item $\mathtt{s1}=3$: m. \item $\mathtt{s2}=2$: m. \item $\mathtt{b}=10$: m. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Fitted transmissivity: 100. \item Hydraulic conductivity: 10. \end{itemize} \subsection{Assumptions and limits} The observation wells must sample the same confined aquifer and exclude well-loss effects. Boundary interference, partial penetration and unsteady records require a richer interpretation. \subsection{Reference} Lohman (1972), Ground-Water Hydraulics, USGS Professional Paper 708. \url{https://pubs.usgs.gov/publication/pp708} Darcy flow, steady pumping and late-time aquifer-test equations. Each app states its own boundary conditions. \end{document}

Engineering Calculator

Engineering Calculation Results