Triaxial test — effective p–q stress invariants

Laboratory & Site Characterization, Stress & Strain

By Foundation Design Method Library

76 Rank #193 Views 1,364
Workspace
QUICK ACCESS
Related engineering apps Cases & data

App-specific engineering geometry and parameter schematic

Theory and Method

\documentclass[11pt]{article} \usepackage{amsmath,amssymb,geometry,xurl,hyperref} \geometry{margin=0.85in} \setlength{\emergencystretch}{3em} \begin{document} \section{Triaxial test - effective p-q stress invariants} \subsection{Purpose} Convert an axisymmetric triaxial measurement into effective stress invariants for a stress-path plot or constitutive calibration. \subsection{Governing equations} \[ p'=\frac{\sigma_1+2\sigma_3}{3}-u,\quad q=\sigma_1-\sigma_3 \] \subsection{Inputs and units} \begin{itemize} \item \textbf{Major total principal stress} ($\mathtt{s1}$): kPa. Default 350. \item \textbf{Minor total principal stress} ($\mathtt{s3}$): kPa. Default 150. \item \textbf{Porewater pressure} ($\mathtt{u}$): kPa. Default 50. \end{itemize} \subsection{How to use the result} Enter values on the stated measurement and unit basis. Intermediate quantities are calculated in the order shown in the downloadable method. Interpret the reported quantities within the physical assumptions below. \begin{itemize} \item Major effective stress: kPa. \item Minor effective stress: kPa. \item Mean effective stress p: kPa. \item Deviator stress q: kPa. \item Stress ratio q/p: -. \end{itemize} \subsection{Worked default example} \begin{itemize} \item Major effective stress: 300 kPa. \item Minor effective stress: 100 kPa. \item Mean effective stress p: 166.666667 kPa. \item Deviator stress q: 200 kPa. \item Stress ratio q/p: 1.2 -. \end{itemize} \subsection{Verification example} A separate hand-checkable or limiting-case benchmark uses the following inputs: \begin{itemize} \item $\mathtt{s1}=300$: kPa. \item $\mathtt{s3}=150$: kPa. \item $\mathtt{u}=50$: kPa. \end{itemize} Expected benchmark quantities: \begin{itemize} \item Mean effective stress p: 150. \item Deviator stress q: 150. \item Stress ratio q/p: 1. \end{itemize} \subsection{Assumptions and limits} Axisymmetric compression convention: sigma2 equals sigma3 and compression is positive. The reported stress ratio requires positive mean effective stress. \subsection{Reference} FHWA NHI-06-088, Soils and Foundations Reference Manual, Volume I (2006). \url{https://www.fhwa.dot.gov/engineering/geotech/pubs/nhi06088.pdf} Soil phase relations, stress transformations, laboratory data reduction, soil classification and consolidation. Equations are implemented independently; this application is not an FHWA product. \end{document}

Engineering Calculator

Engineering Calculation Results