U.S. Environmental Protection Agency
public-link · Publisher-hosted; redistribution permission not established · Checked 2026-11-22Berkeley Pit — mine flooding and hydraulic containment
The flooded open pit and connected underground mine workings require water-level management and treatment. Public monitoring records link hydraulic containment with an ongoing remediation operation.
Project evidence
Design & engineering
Partial recordEPA identifies the Butte Mine Flooding operable unit and continuing treatment. The official monitoring archive provides dated discharge reports; pit water, connected mine water and surrounding aquifers must be represented as a connected system.
Cost & estimating
Not located in cited sourcesA project-specific estimate, bid schedule or final account was not found in the reviewed sources.
Schedule & construction
Not located in cited sourcesA dated project programme was not found in the reviewed sources; develop a study schedule from the documented method.
Completion & performance
Partial recordPublic discharge reports and EPA status material document continuing treatment and monitoring. They are dated operational records, not evidence that treatment can be discontinued.
Engineering methods
Suggested teaching exercise
Capstone project brief
Develop a water-balance and containment assessment for the flooded mine, with sensitivity to uncertain inflow and temporary treatment interruption.
Starting information & inputs
- Use a dated monthly monitoring report for observed discharge and compliance data.
- Identify pit and mine-water levels, the relevant control elevation and its datum, and unmeasured groundwater exchanges.
Suggested deliverables
- Build a time-dependent storage/pumping model that distinguishes observations, calibrated flows and conservative assumptions.
- Develop outage scenarios, monitoring triggers and a recovery pumping strategy with treatment-capacity constraints.
- A quantity takeoff and priced estimate with dated rate sources; separate historical project costs from the study estimate.
- A construction sequence, programme and risk register tied to investigation, access, monitoring and hold points.
Design questions
- How would a stable pit level conceal a change in groundwater capture or treatment demand?
- What evidence is needed before comparing a reported control elevation with survey data recorded in a different vertical datum?
Sources & original records
Thompson and Griffis / Montana Technological University archive
public-link · Publisher-hosted; redistribution permission not established · Checked 2026-11-22PitWatch / Butte Mine Flooding information programme
public-link · Publisher-hosted; redistribution permission not established · Checked 2026-11-22Chris06 · 2013
Project image source. Provider-generated width-limited JPEG preview; no local crop, retouching, added text or recolouring.
public-link · CC BY-SA 4.0 · Checked 2026-11-22